Background: Two methods for detecting synovial fluids alpha defensins are available: the enzyme-linked immunosorbent assay and the lateral flow test. For both, the proper role and accuracy remain uncertain. The purpose of this study was to assess the accuracy of the matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF MS) for alpha defensin detection in synovial fluids of patients with total knee arthroplasty/total hip arthroplasty failures. The hypothesis was that the alpha defensin measurement through MALDI-TOF MS assay could be a high sensitive and specific test for periprosthetic joint infections (PJI) diagnosis as compared with Musculoskeletal Infection Society (MSIS) criteria. Methods: The study included 138 patients. The 2018 MSIS criteria were used to diagnose PJIs. Synovial fluids were assessed for routinely synovial fluid tests and alpha defensin measurement through MALDI-TOF MS. Sensitivity, specificity, overall diagnostic accuracy, positive and negative predictive values, receiver operator curves, and area under the curve were calculated. Results: As per the 2018 MSIS criteria, 59 PJIs (43%) and 79 aseptic failures (57%) were diagnosed. The MALDI-TOF MS assay showed an overall accuracy of 94.9%. The sensitivity was 93%, the specificity was 96%, the positive predictive value was 95%, and the negative predictive value was 95%. Receiver operator curves analysis demonstrates an area under the curve of 0.95 (P <.001). Conclusion: The MALDI-TOF MS assay showed high sensitivity and specificity for alpha defensin detection in case of total knee arthroplasty/total hip arthroplasty failures. The advantages of the technology, such as the few milliliters of sample needed, the rapidity of obtaining results, and the cost-effectiveness of the procedure could make the MALDI-TOF MS alpha defensin assay a useful and widespread test in clinical practice.

Accuracy and Cost-Effectivenss of a Novel Method for Alpha Defensins Measurement in the Diagnosis of Periprosthetic Joint Infections / Iorio, R.; Viglietta, E.; Mazza, D.; Petrucca, A.; Borro, M.; Iolanda, S.; Simmaco, M.; Ferretti, A.. - In: THE JOURNAL OF ARTHROPLASTY. - ISSN 0883-5403. - 36:9(2021), pp. 3275-3281. [10.1016/j.arth.2021.05.013]

Accuracy and Cost-Effectivenss of a Novel Method for Alpha Defensins Measurement in the Diagnosis of Periprosthetic Joint Infections

Iorio R.;Viglietta E.
;
Mazza D.;Borro M.;Simmaco M.;Ferretti A.
2021

Abstract

Background: Two methods for detecting synovial fluids alpha defensins are available: the enzyme-linked immunosorbent assay and the lateral flow test. For both, the proper role and accuracy remain uncertain. The purpose of this study was to assess the accuracy of the matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF MS) for alpha defensin detection in synovial fluids of patients with total knee arthroplasty/total hip arthroplasty failures. The hypothesis was that the alpha defensin measurement through MALDI-TOF MS assay could be a high sensitive and specific test for periprosthetic joint infections (PJI) diagnosis as compared with Musculoskeletal Infection Society (MSIS) criteria. Methods: The study included 138 patients. The 2018 MSIS criteria were used to diagnose PJIs. Synovial fluids were assessed for routinely synovial fluid tests and alpha defensin measurement through MALDI-TOF MS. Sensitivity, specificity, overall diagnostic accuracy, positive and negative predictive values, receiver operator curves, and area under the curve were calculated. Results: As per the 2018 MSIS criteria, 59 PJIs (43%) and 79 aseptic failures (57%) were diagnosed. The MALDI-TOF MS assay showed an overall accuracy of 94.9%. The sensitivity was 93%, the specificity was 96%, the positive predictive value was 95%, and the negative predictive value was 95%. Receiver operator curves analysis demonstrates an area under the curve of 0.95 (P <.001). Conclusion: The MALDI-TOF MS assay showed high sensitivity and specificity for alpha defensin detection in case of total knee arthroplasty/total hip arthroplasty failures. The advantages of the technology, such as the few milliliters of sample needed, the rapidity of obtaining results, and the cost-effectiveness of the procedure could make the MALDI-TOF MS alpha defensin assay a useful and widespread test in clinical practice.
2021
alpha-defensins; biomarker; peri-prosthetic joint infections; pjis; tha; tka
01 Pubblicazione su rivista::01a Articolo in rivista
Accuracy and Cost-Effectivenss of a Novel Method for Alpha Defensins Measurement in the Diagnosis of Periprosthetic Joint Infections / Iorio, R.; Viglietta, E.; Mazza, D.; Petrucca, A.; Borro, M.; Iolanda, S.; Simmaco, M.; Ferretti, A.. - In: THE JOURNAL OF ARTHROPLASTY. - ISSN 0883-5403. - 36:9(2021), pp. 3275-3281. [10.1016/j.arth.2021.05.013]
File allegati a questo prodotto
File Dimensione Formato  
Iorio_Accuracy-and-Cost-Effectivenss_2021.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 646.02 kB
Formato Adobe PDF
646.02 kB Adobe PDF   Contatta l'autore
Iorio_Accuracy-and-Cost-Effectivenss_2021.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 5.17 MB
Formato Adobe PDF
5.17 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1565194
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 6
social impact