Background and study aims The European Society of Gastrointestinal Endoscopy (ESGE) recently issued a quality performance measures document for small bowel capsule endoscopy (SBCE). The aim of this nationwide survey was to explore SBCE practice with ESGE quality measures as a benchmark.Patients and methods A dedicated per-center semi-quantitative questionnaire based on ESGE performance measures for SBCE was created by a group of SBCE experts. One-hundred-eighty-one centers were invited to participate and were asked to calculate performance measures for SBCE performed in 2018. Data were compared with 10 ESGE quality standards for both key and minor performance measures.Results Ninety-one centers (50.3%) participated in the data collection. Overall in the last 5 years (2014-2018), 26,615 SBCEs were performed, 5917 of which were done in 2018. Eighty percent or more of the participating centers reached the minimum standard established by the ESGE Small Bowel Working Group (ESBWG) for four performance measures (indications for SBCE, complete small bowel evaluation, diagnostic yield and retention rate). Conversely, compliance with six minimum standards established by ESBWG concerning adequate bowel preparation, patient selection, timing of SBCE in overt bleeding, appropriate reporting, reading protocols and referral to device-assisted enteroscopy was met by only 15.5%, 10.9%, 31.1%, 67.7%, 53.4%, and 32.2% of centers, respectively.Conclusions The present survey shows significant variability across SBCE centers; only four (4/10: 40%) SBCE procedural minimum standards were met by a relevant proportion of the centers (>= 80%). Our data should help in identifying target areas for quality improvement programs in SBCE.

Quality performance measures for small capsule endoscopy. are the esge quality standards met / Rondonotti, Emanuele; Spada, Cristiano; Cadoni, Sergio; Cannizzaro, Renato; Calabrese, Carlo; de Franchis, Roberto; Elli, Luca; Girelli, Carlo Maria; Hassan, Cesare; Marmo, Riccardo; Riccioni, Maria Elena; Oliva, Salvatore; Scarpulla, Giuseppe; Soncini, Marco; Vecchi, Maurizio; Pennazio, Marco. - In: ENDOSCOPY INTERNATIONAL OPEN. - ISSN 2364-3722. - 9:2(2021), pp. E122-E129. [10.1055/a-1319-0742]

Quality performance measures for small capsule endoscopy. are the esge quality standards met

Oliva, Salvatore;
2021

Abstract

Background and study aims The European Society of Gastrointestinal Endoscopy (ESGE) recently issued a quality performance measures document for small bowel capsule endoscopy (SBCE). The aim of this nationwide survey was to explore SBCE practice with ESGE quality measures as a benchmark.Patients and methods A dedicated per-center semi-quantitative questionnaire based on ESGE performance measures for SBCE was created by a group of SBCE experts. One-hundred-eighty-one centers were invited to participate and were asked to calculate performance measures for SBCE performed in 2018. Data were compared with 10 ESGE quality standards for both key and minor performance measures.Results Ninety-one centers (50.3%) participated in the data collection. Overall in the last 5 years (2014-2018), 26,615 SBCEs were performed, 5917 of which were done in 2018. Eighty percent or more of the participating centers reached the minimum standard established by the ESGE Small Bowel Working Group (ESBWG) for four performance measures (indications for SBCE, complete small bowel evaluation, diagnostic yield and retention rate). Conversely, compliance with six minimum standards established by ESBWG concerning adequate bowel preparation, patient selection, timing of SBCE in overt bleeding, appropriate reporting, reading protocols and referral to device-assisted enteroscopy was met by only 15.5%, 10.9%, 31.1%, 67.7%, 53.4%, and 32.2% of centers, respectively.Conclusions The present survey shows significant variability across SBCE centers; only four (4/10: 40%) SBCE procedural minimum standards were met by a relevant proportion of the centers (>= 80%). Our data should help in identifying target areas for quality improvement programs in SBCE.
2021
small bowel; capsule endoscopy; esge
01 Pubblicazione su rivista::01a Articolo in rivista
Quality performance measures for small capsule endoscopy. are the esge quality standards met / Rondonotti, Emanuele; Spada, Cristiano; Cadoni, Sergio; Cannizzaro, Renato; Calabrese, Carlo; de Franchis, Roberto; Elli, Luca; Girelli, Carlo Maria; Hassan, Cesare; Marmo, Riccardo; Riccioni, Maria Elena; Oliva, Salvatore; Scarpulla, Giuseppe; Soncini, Marco; Vecchi, Maurizio; Pennazio, Marco. - In: ENDOSCOPY INTERNATIONAL OPEN. - ISSN 2364-3722. - 9:2(2021), pp. E122-E129. [10.1055/a-1319-0742]
File allegati a questo prodotto
File Dimensione Formato  
Rondonotti_Quality-performance-measures_2021.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 745.32 kB
Formato Adobe PDF
745.32 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1560224
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 12
social impact