The accurate determination of trace elements in vegetable edible oils is still an analytical challenge, owing to their low concentration levels and the complex matrix of the vegetable oils. The aim of this study was to develop a fast and simple analytical method to quantify 45 elements in small mass samples (0.5 g) of extra virgin olive oils by inductively coupled plasma mass spectrometry. To evaluate the best and fastest sample preparation procedure, ultrasonic extraction and wet digestion methods were compared using oil certified reference material with different reagent mixtures, reagent volumes, and times for sample extraction or digestion. The use of 5 mL reagent mixture F [10% (v/v) HNO3 and H2O2, 2:1 (v/v)] for sample digestion in a water bath (95 ◦C, 40 min) was found to produce satisfactory results in all cases as validated from sample recovery experiments over three different extra virgin olive oil samples.
An optimized method for sample preparation and elemental analysis of extra-virgin olive oil by inductively coupled plasma mass spectrometry / Astolfi, Maria Luisa; Marconi, Elisabetta; Vitiello, Giulia; Massimi, Lorenzo. - In: FOOD CHEMISTRY. - ISSN 0308-8146. - 360:(2021), pp. 1-8. [10.1016/j.foodchem.2021.130027]
An optimized method for sample preparation and elemental analysis of extra-virgin olive oil by inductively coupled plasma mass spectrometry
Astolfi, Maria Luisa
Primo
;Marconi, Elisabetta;Vitiello, Giulia;Massimi, Lorenzo
2021
Abstract
The accurate determination of trace elements in vegetable edible oils is still an analytical challenge, owing to their low concentration levels and the complex matrix of the vegetable oils. The aim of this study was to develop a fast and simple analytical method to quantify 45 elements in small mass samples (0.5 g) of extra virgin olive oils by inductively coupled plasma mass spectrometry. To evaluate the best and fastest sample preparation procedure, ultrasonic extraction and wet digestion methods were compared using oil certified reference material with different reagent mixtures, reagent volumes, and times for sample extraction or digestion. The use of 5 mL reagent mixture F [10% (v/v) HNO3 and H2O2, 2:1 (v/v)] for sample digestion in a water bath (95 ◦C, 40 min) was found to produce satisfactory results in all cases as validated from sample recovery experiments over three different extra virgin olive oil samples.File | Dimensione | Formato | |
---|---|---|---|
Astolfi_An-optimized-method_2021.pdf
solo gestori archivio
Note: https://www.sciencedirect.com/science/article/pii/S0308814621010335?dgcid=author
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
603.58 kB
Formato
Adobe PDF
|
603.58 kB | Adobe PDF | Contatta l'autore |
Astolfi_supplementary_An-optimized-method_2021.pdf
accesso aperto
Note: supplementary material
Tipologia:
Altro materiale allegato
Licenza:
Creative commons
Dimensione
135.16 kB
Formato
Adobe PDF
|
135.16 kB | Adobe PDF | |
Astolfi_post-print_An-optimized-method_2021.pdf
accesso aperto
Note: Accepted manuscript
Tipologia:
Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza:
Creative commons
Dimensione
1.11 MB
Formato
Adobe PDF
|
1.11 MB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.