Background. EndoFaster® analyzes gastric juice in real time during gastroscopy allowing the detection of hypo-achlorhydric conditions, like corpus atrophic gastritis. Narrow-band imaging (NBI) endoscopy allows to accurately detect and perform target biopsies in areas of intestinal metaplasia, a histological change often associated to corpus atrophic gastritis. Aims. To compare the diagnostic accuracy of EndoFaster® with histological evaluation for corpus atrophic gastritis through high-resolution (HR) NBI targeted biopsies. Methods. Prospective study on consecutive adult patients undergoing gastroscopy between April and November 2018. Patients in therapy with proton pump inhibitors, previous gastric surgery, and/or known gastric neoplasia were excluded. At the beginning of gastroscopy, gastric juice was aspirated and analyzed by EndoFaster® in 15 seconds. Endoscopists were blinded to the report of EndoFaster®. Evaluation of gastric mucosa in HR-white light was firstly performed, then with HR-NBI allowing to perform targeted biopsies on areas suspected for intestinal metaplasia; otherwise, biopsies were performed according to the updated Sydney System protocol and sent for histopathological evaluation. Results. Overall, 124 patients were included [64% F; 56 (18-85) years]. Corpus atrophic gastritis was present in 41.9% of patients. EndoFaster® showed an accuracy for corpus atrophic gastritis diagnosis, compared to histopathological evaluation as gold standard, of 87.1% and a sensitivity, specificity, PPV, and NPV of 78.8%, 93.1%, 89.1%, and 85.9%, respectively. pH showed a positive correlation with the severity score of atrophy (r = 0.67, 95% CI: 0.73-0.81, and p < 0.0001). EndoFaster® allowed to diagnose corpus atrophic gastritis in 3.7% of patients negative to NBI (corpus atrophic gastritis without intestinal metaplasia). Conclusion. EndoFaster® seems a promising tool to diagnose corpus atrophic gastritis. The evaluation of hypo-achlorhydria during gastroscopy can address bioptic sampling in corpus atrophic gastritis patients without intestinal metaplasia.

Diagnostic Accuracy of EndoFaster® and Narrow-Band Imaging Endoscopy in Patients with Impaired Gastric Acid Secretion. A Real-Time Prospective Study / Cazzato, M.; Esposito, G.; Galli, G.; Pilozzi, E.; Lahner, E.; Corleto, V. D.; Zullo, A.; Di Giulio, E.; Annibale, B.. - In: GASTROENTEROLOGY RESEARCH AND PRACTICE. - ISSN 1687-630X. - 2021:Mar 20(2021), pp. 1-8. [10.1155/2021/6616334]

Diagnostic Accuracy of EndoFaster® and Narrow-Band Imaging Endoscopy in Patients with Impaired Gastric Acid Secretion. A Real-Time Prospective Study

Cazzato, M.;Esposito, G.;Galli, G.;Pilozzi, E.;Lahner, E.;Corleto, V. D.;Di Giulio, E.;Annibale, B.
2021

Abstract

Background. EndoFaster® analyzes gastric juice in real time during gastroscopy allowing the detection of hypo-achlorhydric conditions, like corpus atrophic gastritis. Narrow-band imaging (NBI) endoscopy allows to accurately detect and perform target biopsies in areas of intestinal metaplasia, a histological change often associated to corpus atrophic gastritis. Aims. To compare the diagnostic accuracy of EndoFaster® with histological evaluation for corpus atrophic gastritis through high-resolution (HR) NBI targeted biopsies. Methods. Prospective study on consecutive adult patients undergoing gastroscopy between April and November 2018. Patients in therapy with proton pump inhibitors, previous gastric surgery, and/or known gastric neoplasia were excluded. At the beginning of gastroscopy, gastric juice was aspirated and analyzed by EndoFaster® in 15 seconds. Endoscopists were blinded to the report of EndoFaster®. Evaluation of gastric mucosa in HR-white light was firstly performed, then with HR-NBI allowing to perform targeted biopsies on areas suspected for intestinal metaplasia; otherwise, biopsies were performed according to the updated Sydney System protocol and sent for histopathological evaluation. Results. Overall, 124 patients were included [64% F; 56 (18-85) years]. Corpus atrophic gastritis was present in 41.9% of patients. EndoFaster® showed an accuracy for corpus atrophic gastritis diagnosis, compared to histopathological evaluation as gold standard, of 87.1% and a sensitivity, specificity, PPV, and NPV of 78.8%, 93.1%, 89.1%, and 85.9%, respectively. pH showed a positive correlation with the severity score of atrophy (r = 0.67, 95% CI: 0.73-0.81, and p < 0.0001). EndoFaster® allowed to diagnose corpus atrophic gastritis in 3.7% of patients negative to NBI (corpus atrophic gastritis without intestinal metaplasia). Conclusion. EndoFaster® seems a promising tool to diagnose corpus atrophic gastritis. The evaluation of hypo-achlorhydria during gastroscopy can address bioptic sampling in corpus atrophic gastritis patients without intestinal metaplasia.
2021
endofaster; narrow band imaging; nbi; corpus atrophic gastritis; hypochloridria; gastroscopy; upper gi endoscopy
01 Pubblicazione su rivista::01a Articolo in rivista
Diagnostic Accuracy of EndoFaster® and Narrow-Band Imaging Endoscopy in Patients with Impaired Gastric Acid Secretion. A Real-Time Prospective Study / Cazzato, M.; Esposito, G.; Galli, G.; Pilozzi, E.; Lahner, E.; Corleto, V. D.; Zullo, A.; Di Giulio, E.; Annibale, B.. - In: GASTROENTEROLOGY RESEARCH AND PRACTICE. - ISSN 1687-630X. - 2021:Mar 20(2021), pp. 1-8. [10.1155/2021/6616334]
File allegati a questo prodotto
File Dimensione Formato  
Cazzato_Diagnostic-Accuracy_2021.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 469.59 kB
Formato Adobe PDF
469.59 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1532488
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
social impact