This paper analyzes the intelligent use of time-varying electrical load via developing efficient energy utilization patterns using demand-side management (DSM) strategies. This approach helps distribution utilities decrease maximum demand and electrical energy billing costs. A case study of DSM implementation of electric energy utility for an educational building Alagappa Chettiar Government College of Engineering and Technology (ACGCET) campus was simulated. The new optimum energy load model was established for peak and off-peak periods from the system's existing load profile using peak clipping and load shifting DSM techniques. The result reflects a significant reduction in maximum demand from 189 kW to 170 kW and a reduction in annual electricity billing cost from $11,340 to $10,200 (approximately 10%) in the upgraded system. This work highlights the importance of time of day (TOD) tariff structure consumers that aid reduction in their distribution system's maximum demand and demand charges. Copyright:

Load shifting and peak clipping for reducing energy consumption in an indian university campus / Dharani, R.; Balasubramonian, M.; Babu, T. S.; Nastasi, B.. - In: ENERGIES. - ISSN 1996-1073. - 14:3(2021). [10.3390/en14030558]

Load shifting and peak clipping for reducing energy consumption in an indian university campus

Nastasi B.
2021

Abstract

This paper analyzes the intelligent use of time-varying electrical load via developing efficient energy utilization patterns using demand-side management (DSM) strategies. This approach helps distribution utilities decrease maximum demand and electrical energy billing costs. A case study of DSM implementation of electric energy utility for an educational building Alagappa Chettiar Government College of Engineering and Technology (ACGCET) campus was simulated. The new optimum energy load model was established for peak and off-peak periods from the system's existing load profile using peak clipping and load shifting DSM techniques. The result reflects a significant reduction in maximum demand from 189 kW to 170 kW and a reduction in annual electricity billing cost from $11,340 to $10,200 (approximately 10%) in the upgraded system. This work highlights the importance of time of day (TOD) tariff structure consumers that aid reduction in their distribution system's maximum demand and demand charges. Copyright:
2021
building energy flexibility; energy saving; homer software; loaf shifting; peack clipping
01 Pubblicazione su rivista::01a Articolo in rivista
Load shifting and peak clipping for reducing energy consumption in an indian university campus / Dharani, R.; Balasubramonian, M.; Babu, T. S.; Nastasi, B.. - In: ENERGIES. - ISSN 1996-1073. - 14:3(2021). [10.3390/en14030558]
File allegati a questo prodotto
File Dimensione Formato  
Dharani_Load shifting_2021.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 5.23 MB
Formato Adobe PDF
5.23 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1527868
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 17
social impact