The paper proposes a novel instrument for the eddy current non-destructive testing on conductive materials. The instrument is composed by a smart eddy current probe, based on a Giant Magneto Resistance sensor, and a suitable processing unit. Key features of the proposed instrument are the capability to detect, locate and characterize thin defects as superficial and sub-superficial cracks. The cost effective of the proposal, and the metrological performances of the realized instrument make it suited in several applications fields such as aerospace and maritime. In the paper the steps followed toward the instrument realization are described together with a preliminary experimental characterization

GMR-based instrument for ECT on conductive planar specimens / Betta, Giovanni; Ferrigno, Luigi; Laracca, Marco. - (2010), pp. 845-849. (Intervento presentato al convegno 2010 IEEE Instrumentation and measurement technology conference, I2MTC 2010 tenutosi a Austin, TX; United States) [10.1109/IMTC.2010.5488026].

GMR-based instrument for ECT on conductive planar specimens

Marco Laracca
2010

Abstract

The paper proposes a novel instrument for the eddy current non-destructive testing on conductive materials. The instrument is composed by a smart eddy current probe, based on a Giant Magneto Resistance sensor, and a suitable processing unit. Key features of the proposed instrument are the capability to detect, locate and characterize thin defects as superficial and sub-superficial cracks. The cost effective of the proposal, and the metrological performances of the realized instrument make it suited in several applications fields such as aerospace and maritime. In the paper the steps followed toward the instrument realization are described together with a preliminary experimental characterization
2010
2010 IEEE Instrumentation and measurement technology conference, I2MTC 2010
eddy current testing; giant magnetoresistance (GMR); Mmagnetic field measurement
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
GMR-based instrument for ECT on conductive planar specimens / Betta, Giovanni; Ferrigno, Luigi; Laracca, Marco. - (2010), pp. 845-849. (Intervento presentato al convegno 2010 IEEE Instrumentation and measurement technology conference, I2MTC 2010 tenutosi a Austin, TX; United States) [10.1109/IMTC.2010.5488026].
File allegati a questo prodotto
File Dimensione Formato  
Betta_GMR-based instrument_2010.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.07 MB
Formato Adobe PDF
1.07 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1526314
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 4
social impact