The factors affecting polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) formation were studied in sewage sludge incineration tests carried out on a demonstrative plant. The plant includes a circulating fluidised bed furnace (FBF) and a rotary kiln furnace (RKF), operating alternatively. During the tests sewage sludge was spiked with chlorinated hydrocarbons and the operating parameters of the afterburning chamber were varied. PCDD/F were sampled in each test before the bag filter, thus collecting the above contaminants before abatement systems. From the tests it appeared that PCDD/F were always produced in more abundance in the tests carried out by FBF than by RKF. The higher PCDD/F concentrations in the tests by FBF were reached when sewage sludge was spiked with a high dosage of a surrogate organic mixture of chlorinated hydrocarbons and when the afterburning chamber was used only as transit equipment with the burner off. The distribution of the different PCDD/F homologues was compared. P(5)CDFs were generally the prevalent fraction, with very few exceptions for the tests by RKF at high temperature of the afterburning chamber. As for FBF tests, it was found that the PCDD/F homologue profile depends on the afterburning chamber temperature. (C) 2003 Elsevier Ltd. All rights reserved.

Dioxins and furans formation in pilot incineration tests of sewage sludge spiked with organic chlorine / Mininni, G; Sbrilli, A; Guerriero, E; Rotatori, M. - In: CHEMOSPHERE. - ISSN 0045-6535. - 54:9(2004), pp. 1337-1350. [10.1016/S0045-6535(03)00252-2]

Dioxins and furans formation in pilot incineration tests of sewage sludge spiked with organic chlorine

Guerriero E;
2004

Abstract

The factors affecting polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) formation were studied in sewage sludge incineration tests carried out on a demonstrative plant. The plant includes a circulating fluidised bed furnace (FBF) and a rotary kiln furnace (RKF), operating alternatively. During the tests sewage sludge was spiked with chlorinated hydrocarbons and the operating parameters of the afterburning chamber were varied. PCDD/F were sampled in each test before the bag filter, thus collecting the above contaminants before abatement systems. From the tests it appeared that PCDD/F were always produced in more abundance in the tests carried out by FBF than by RKF. The higher PCDD/F concentrations in the tests by FBF were reached when sewage sludge was spiked with a high dosage of a surrogate organic mixture of chlorinated hydrocarbons and when the afterburning chamber was used only as transit equipment with the burner off. The distribution of the different PCDD/F homologues was compared. P(5)CDFs were generally the prevalent fraction, with very few exceptions for the tests by RKF at high temperature of the afterburning chamber. As for FBF tests, it was found that the PCDD/F homologue profile depends on the afterburning chamber temperature. (C) 2003 Elsevier Ltd. All rights reserved.
2004
01 Pubblicazione su rivista::01a Articolo in rivista
Dioxins and furans formation in pilot incineration tests of sewage sludge spiked with organic chlorine / Mininni, G; Sbrilli, A; Guerriero, E; Rotatori, M. - In: CHEMOSPHERE. - ISSN 0045-6535. - 54:9(2004), pp. 1337-1350. [10.1016/S0045-6535(03)00252-2]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1500799
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 41
  • ???jsp.display-item.citation.isi??? 38
social impact