The purpose of this study is to evaluate at a mid-term follow up, the radiological survival of an uncemented humeral stem in shoulder arthroplasty. One hundred and twenty-six replacements including hemi (HA), total (TSA) and reverse (RSA) implanted from 1999 to 2008 were reviewed at a mean follow up of 7.2 years (48-144 months). The same uncemented triconical stem (SMR, Lima Corporate) was implanted. There were: 23 HSA, 43 TSA, 60 RSA. An independent observer evaluated all the patients with Constant Score. A radiologic analysis by an expert radiologist and an orthopaedic surgeon was performed: humeral component-bone interface was divided in seven zones. They judged a mobilisation if a migration or tilt of the humeral implant or if≥ 2 mm radiolucent line in at least three zones was present. Chi-squared test, Fisher test and analysis of variance were performed and a p<0.05 was considered statistically significant. No major radiological signs of loosening and no tilt or migration of the humeral component were found. Only 23 (18.2%) patients had no RL around the humeral implant. In the remaining 103 (81.7%) implants: 96 (76.1%) presented RL less than 2 mm, particularly 75 (59.5%) in less than 3 zones and 21 (16.6%) in more than 3 zones. Of the remaining 7 (5.5%) implants the presence of RL of 2 mm or greater in only one zone was seen. Apart from sepsis no revision was performed for humeral component loosening. Although a high rate of RL, uncemented humeral stem has an excellent survivorship at a mid-term follow up. Relationship between presence, position and depth of RL and internal stress shielding is commonly observed but does not appear to compromise quality of fixation or clinical outcomes in shoulder arthroplasty.

Do radiolucent lines and stress shielding of the humeral shaft really matter in shoulder arthroplasty? / Castagna, A; Delle Rose, G; De Giorgi, S; Gumina, S; Garofalo, R; Borroni, M. - In: JOURNAL OF BIOLOGICAL REGULATORS & HOMEOSTATIC AGENTS. - ISSN 0393-974X. - 34:4 Suppl. 3(2020), pp. 309-314. (Intervento presentato al convegno 21 Congress of the Italian Orthopaedic Research Society tenutosi a Torino).

Do radiolucent lines and stress shielding of the humeral shaft really matter in shoulder arthroplasty?

Gumina, S;
2020

Abstract

The purpose of this study is to evaluate at a mid-term follow up, the radiological survival of an uncemented humeral stem in shoulder arthroplasty. One hundred and twenty-six replacements including hemi (HA), total (TSA) and reverse (RSA) implanted from 1999 to 2008 were reviewed at a mean follow up of 7.2 years (48-144 months). The same uncemented triconical stem (SMR, Lima Corporate) was implanted. There were: 23 HSA, 43 TSA, 60 RSA. An independent observer evaluated all the patients with Constant Score. A radiologic analysis by an expert radiologist and an orthopaedic surgeon was performed: humeral component-bone interface was divided in seven zones. They judged a mobilisation if a migration or tilt of the humeral implant or if≥ 2 mm radiolucent line in at least three zones was present. Chi-squared test, Fisher test and analysis of variance were performed and a p<0.05 was considered statistically significant. No major radiological signs of loosening and no tilt or migration of the humeral component were found. Only 23 (18.2%) patients had no RL around the humeral implant. In the remaining 103 (81.7%) implants: 96 (76.1%) presented RL less than 2 mm, particularly 75 (59.5%) in less than 3 zones and 21 (16.6%) in more than 3 zones. Of the remaining 7 (5.5%) implants the presence of RL of 2 mm or greater in only one zone was seen. Apart from sepsis no revision was performed for humeral component loosening. Although a high rate of RL, uncemented humeral stem has an excellent survivorship at a mid-term follow up. Relationship between presence, position and depth of RL and internal stress shielding is commonly observed but does not appear to compromise quality of fixation or clinical outcomes in shoulder arthroplasty.
2020
21 Congress of the Italian Orthopaedic Research Society
fracture; implant; shoulder arthroplasty; uncemented humeral stem; follow-Up studies; humans; humerus; prostheses and implants; range of motion; articular; retrospective studies;treatment outcome; arthroplasty; replacement; shoulder; shoulder joint
04 Pubblicazione in atti di convegno::04c Atto di convegno in rivista
Do radiolucent lines and stress shielding of the humeral shaft really matter in shoulder arthroplasty? / Castagna, A; Delle Rose, G; De Giorgi, S; Gumina, S; Garofalo, R; Borroni, M. - In: JOURNAL OF BIOLOGICAL REGULATORS & HOMEOSTATIC AGENTS. - ISSN 0393-974X. - 34:4 Suppl. 3(2020), pp. 309-314. (Intervento presentato al convegno 21 Congress of the Italian Orthopaedic Research Society tenutosi a Torino).
File allegati a questo prodotto
File Dimensione Formato  
Castagna_Radiolucent_2020.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 366.29 kB
Formato Adobe PDF
366.29 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1496902
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact