In ITER, the window assemblies will be subjected to the combination of loads due to stray radiation and neutron streaming. Therefore, adequate tests are needed to qualify the windows for the hostile environmental conditions. In ITER, two main systems will generate high power waves in the millimeter range: the Collective Thomson Scattering (CTS) system, with a total power of 1 MW at 60 GHz, and the Electron Cyclotron Resonant Heating (ECRH) system, with a maximum power of 20 MW at 170 GHz. In particular operating conditions, a significant power fraction can be deflected in other ports as stray radiation. High levels of stray radiation could damage diagnostic windows that are safety relevant components. The radiation absorbed by the fused silica window assemblies on ports #11 and #12 have been evaluated in detail. The possible effects of gamma and neutron flux on the dielectric permittivity and loss tangent, determining the absorption, have also been reviewed.

Stray millimeter-wave radiation loads on ITER fused silica windows / Gelfusa, M.; Simonetto, A.; Mirizzi, F.; Peluso, E.; Calamida, A.; Bruschi, A.; Donnini, R.; Sozzi, C.; Romanelli, F.; Cuce, D.; Nobili, M.; Lazzari, A.; Vila, R.; Sirinelli, A.; Maquet, P.. - In: FUSION ENGINEERING AND DESIGN. - ISSN 0920-3796. - 146:(2019), pp. 308-311. [10.1016/j.fusengdes.2018.12.052]

Stray millimeter-wave radiation loads on ITER fused silica windows

Peluso E.;Calamida A.;
2019

Abstract

In ITER, the window assemblies will be subjected to the combination of loads due to stray radiation and neutron streaming. Therefore, adequate tests are needed to qualify the windows for the hostile environmental conditions. In ITER, two main systems will generate high power waves in the millimeter range: the Collective Thomson Scattering (CTS) system, with a total power of 1 MW at 60 GHz, and the Electron Cyclotron Resonant Heating (ECRH) system, with a maximum power of 20 MW at 170 GHz. In particular operating conditions, a significant power fraction can be deflected in other ports as stray radiation. High levels of stray radiation could damage diagnostic windows that are safety relevant components. The radiation absorbed by the fused silica window assemblies on ports #11 and #12 have been evaluated in detail. The possible effects of gamma and neutron flux on the dielectric permittivity and loss tangent, determining the absorption, have also been reviewed.
2019
CTS; ECRH; fused silica; stray radiation; vacuum windows
01 Pubblicazione su rivista::01a Articolo in rivista
Stray millimeter-wave radiation loads on ITER fused silica windows / Gelfusa, M.; Simonetto, A.; Mirizzi, F.; Peluso, E.; Calamida, A.; Bruschi, A.; Donnini, R.; Sozzi, C.; Romanelli, F.; Cuce, D.; Nobili, M.; Lazzari, A.; Vila, R.; Sirinelli, A.; Maquet, P.. - In: FUSION ENGINEERING AND DESIGN. - ISSN 0920-3796. - 146:(2019), pp. 308-311. [10.1016/j.fusengdes.2018.12.052]
File allegati a questo prodotto
File Dimensione Formato  
Calamida_Millimeter-wave-radiation.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 424.76 kB
Formato Adobe PDF
424.76 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1487847
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact