Background and Objectives: The use of synthetic cannabinoids has increased around the world. As a result, the implementation of accurate analysis in human biological matrices is relevant and fundamental. Two different analytical technologies, ultra-high-performance liquid chromatography-high-resolution mass spectrometry (UHPLC-HRMS) and high-sensitivity gas chromatography-mass spectrometry (GC-MS) were used for the determination of three synthetic cannabinoids JWH-122, JWH 210, UR-144 and their metabolites in urine of consumers. Materials and Methods: Sample preparation included an initial hydrolysis with β-glucuronidase and liquid-liquid extraction. The UHPLC-HRMS method included a Kinetex 2.6 u Biphenyl 100A (100 × 2.1 mm, 2.6 µm) (Phenomenex, Italy) column with a gradient mobile phase consisting of mobile phase A (ammonium formate 2mM in water, 0.1% formic acid) and mobile phase B (ammonium formate 2mM in methanol/acetonitrile 50:50 (v/v), 0.1% formic acid) and a full-scan data-dependent MS2 (ddMS2) mode was used (mass range 100–1000 m/z). The GC-MS method employed an ultra-Inert Intuvo GC column (HP-5MS UI, 30 m × 250 µm i.d, film thickness 0.25 µm; Agilent Technologies, Santa Clara, CA, USA) and electron-impact (EI) mass spectra were recorded in total ion monitoring mode (scan range 40–550 m/z). Results: Both methods have been successfully used for screening of parent synthetic cannabinoids and their metabolites in urine samples of consumers. Conclusions: The screening method applied JWH-122, JWH-210, UR-144 and their metabolites in urine of consumers can be applied to other compounds of the JWH family.

Uhplc-hrms and gc-ms screening of a selection of synthetic cannabinoids and metabolites in urine of consumers / Pellegrini, M.; Marchei, E.; Papaseit, E.; Farre, M.; Zaami, S.. - In: MEDICINA. - ISSN 1010-660X. - 56:8(2020), pp. 1-9. [10.3390/medicina56080408]

Uhplc-hrms and gc-ms screening of a selection of synthetic cannabinoids and metabolites in urine of consumers

Marchei E.
Secondo
;
Zaami S.
Ultimo
2020

Abstract

Background and Objectives: The use of synthetic cannabinoids has increased around the world. As a result, the implementation of accurate analysis in human biological matrices is relevant and fundamental. Two different analytical technologies, ultra-high-performance liquid chromatography-high-resolution mass spectrometry (UHPLC-HRMS) and high-sensitivity gas chromatography-mass spectrometry (GC-MS) were used for the determination of three synthetic cannabinoids JWH-122, JWH 210, UR-144 and their metabolites in urine of consumers. Materials and Methods: Sample preparation included an initial hydrolysis with β-glucuronidase and liquid-liquid extraction. The UHPLC-HRMS method included a Kinetex 2.6 u Biphenyl 100A (100 × 2.1 mm, 2.6 µm) (Phenomenex, Italy) column with a gradient mobile phase consisting of mobile phase A (ammonium formate 2mM in water, 0.1% formic acid) and mobile phase B (ammonium formate 2mM in methanol/acetonitrile 50:50 (v/v), 0.1% formic acid) and a full-scan data-dependent MS2 (ddMS2) mode was used (mass range 100–1000 m/z). The GC-MS method employed an ultra-Inert Intuvo GC column (HP-5MS UI, 30 m × 250 µm i.d, film thickness 0.25 µm; Agilent Technologies, Santa Clara, CA, USA) and electron-impact (EI) mass spectra were recorded in total ion monitoring mode (scan range 40–550 m/z). Results: Both methods have been successfully used for screening of parent synthetic cannabinoids and their metabolites in urine samples of consumers. Conclusions: The screening method applied JWH-122, JWH-210, UR-144 and their metabolites in urine of consumers can be applied to other compounds of the JWH family.
2020
gas chromatography-mass spectrometry; high-resolution mass spectrometry; liquid chromatography; synthetic cannabinoids; urine
01 Pubblicazione su rivista::01a Articolo in rivista
Uhplc-hrms and gc-ms screening of a selection of synthetic cannabinoids and metabolites in urine of consumers / Pellegrini, M.; Marchei, E.; Papaseit, E.; Farre, M.; Zaami, S.. - In: MEDICINA. - ISSN 1010-660X. - 56:8(2020), pp. 1-9. [10.3390/medicina56080408]
File allegati a questo prodotto
File Dimensione Formato  
Pellegrini_UHPLC-HRMS_2020.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 1.08 MB
Formato Adobe PDF
1.08 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1477226
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 12
social impact