We describe the design and in–flight performance of the cryostat and the self–contained 3He refrigerator for the OLIMPO balloon–borne experiment, a spectrophotometer to measure the Sunyaev–Zel'dovich effect in clusters of galaxies. The 3He refrigerator provides the 0.3 K operation temperature for the four arrays of kinetic inductance detectors working in 4 bands centered at 150, 250, 350 and 460 GHz. The cryostat provides the 1.65 K base temperature for the 3He refrigerator, and cools down the reimaging optics and the filters chain at about 2 K. The integrated system was designed for a hold time of about 15 days, to achieve the sensitivity required by the planned OLIMPO observations, and successfully operated during the first long–duration stratospheric flight of OLIMPO in July 2018. The cryostat features two tanks, one for liquid nitrogen and the other one for liquid helium. The long hold time has been achieved by means of custom stiff G10 fiberglass tubes support, which ensures low thermal conductivity and remarkable structural stiffness; multi–layer superinsulation, and a vapour cooled shield, all reducing the heat load on the liquid helium tank. The system was tested in the lab, with more than 15 days of unmanned operations, and then in the long duration balloon flight in the stratosphere. In both cases, the detector temperature was below 300 mK, with thermal stability better than ±0.5 mK. The system also operated successfully in the long duration stratospheric balloon flight.

The long duration cryogenic system of the OLIMPO balloon–borne experiment: Design and in–flight performance / Coppolecchia, A.; Lamagna, L.; Masi, S.; Ade, P. A. R.; Amico, G.; Battistelli, E. S.; de Bernardis, P.; Columbro, F.; Conversi, L.; D'Alessandro, G.; De Petris, M.; Gervasi, M.; Nati, F.; Nati, L.; Paiella, A.; Piacentini, F.; Pisano, G.; Presta, G.; Schillaci, A.; Tucker, C.; Zannoni, M.. - In: CRYOGENICS. - ISSN 0011-2275. - 110:(2020), p. 103129. [10.1016/j.cryogenics.2020.103129]

The long duration cryogenic system of the OLIMPO balloon–borne experiment: Design and in–flight performance

Coppolecchia A.
;
Lamagna L.;Masi S.;Amico G.;Battistelli E. S.;de Bernardis P.;Columbro F.;D'Alessandro G.;De Petris M.;Nati F.;Paiella A.;Piacentini F.;Pisano G.;Presta G.;
2020

Abstract

We describe the design and in–flight performance of the cryostat and the self–contained 3He refrigerator for the OLIMPO balloon–borne experiment, a spectrophotometer to measure the Sunyaev–Zel'dovich effect in clusters of galaxies. The 3He refrigerator provides the 0.3 K operation temperature for the four arrays of kinetic inductance detectors working in 4 bands centered at 150, 250, 350 and 460 GHz. The cryostat provides the 1.65 K base temperature for the 3He refrigerator, and cools down the reimaging optics and the filters chain at about 2 K. The integrated system was designed for a hold time of about 15 days, to achieve the sensitivity required by the planned OLIMPO observations, and successfully operated during the first long–duration stratospheric flight of OLIMPO in July 2018. The cryostat features two tanks, one for liquid nitrogen and the other one for liquid helium. The long hold time has been achieved by means of custom stiff G10 fiberglass tubes support, which ensures low thermal conductivity and remarkable structural stiffness; multi–layer superinsulation, and a vapour cooled shield, all reducing the heat load on the liquid helium tank. The system was tested in the lab, with more than 15 days of unmanned operations, and then in the long duration balloon flight in the stratosphere. In both cases, the detector temperature was below 300 mK, with thermal stability better than ±0.5 mK. The system also operated successfully in the long duration stratospheric balloon flight.
2020
Balloon-borne experiment; Helium vapor cooled shield; Long duration ; 3; He sorption fridge; Superinsulation; Wet cryostat
01 Pubblicazione su rivista::01a Articolo in rivista
The long duration cryogenic system of the OLIMPO balloon–borne experiment: Design and in–flight performance / Coppolecchia, A.; Lamagna, L.; Masi, S.; Ade, P. A. R.; Amico, G.; Battistelli, E. S.; de Bernardis, P.; Columbro, F.; Conversi, L.; D'Alessandro, G.; De Petris, M.; Gervasi, M.; Nati, F.; Nati, L.; Paiella, A.; Piacentini, F.; Pisano, G.; Presta, G.; Schillaci, A.; Tucker, C.; Zannoni, M.. - In: CRYOGENICS. - ISSN 0011-2275. - 110:(2020), p. 103129. [10.1016/j.cryogenics.2020.103129]
File allegati a questo prodotto
File Dimensione Formato  
Coppolecchia_The long duration cryogenic_2020.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 2.61 MB
Formato Adobe PDF
2.61 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1470106
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 3
social impact