(1) Background: The aim of the work is to identify some imaging parameters in osteogenesis imperfecta to assist the dentist in the diagnosis, planning, and orthodontic treatment of Osteogenesis Imperfecta (OI) using 3D cone beam Computed Tomography (CBCT) and the Double Energy X-ray Absorptiometry (DEXA) technique. (2) Methods: 14 patients (9 males and 5 females; aged mean ± SD 15 ± 1.5) with a clinical-radiological diagnosis of OI were analyzed and divided into mild and moderate to severe forms. The patients’ samples were compared with a control group of 14 patients (8 males and 6 females; aged mean ± SD 15 ± 1.7), free from osteoporotic pathologies. (3) Results: The statistical analysis allowed us to collect four datasets: in the first dataset (C1 sick population vs. C1 healthy population), the t-test showed a p-value < 0.0001; in the second dataset (C2 sick population vs. C2 healthy population), the t-test showed a p-value < 0.0001; in the third dataset (parameter X of the sick population vs. parameter X of the healthy population), the t-test showed a p-value < 0.0001; in the fourth dataset the bone mineralometry (BMD) value detected by the DEXA technique compared to the C2 value of the OI affected population only) the Welch–Satterthwaite test showed a p-value < 0.0001. (4) Conclusions: The research has produced specific imaging parameters that assist the dentist in making diagnostic decisions in OI patients. This study shows that patients with OI have a characteristic chin-bearing symphysis, thinned, and narrowed towards the center, configuring it with a constant “hourglass” appearance, not reported so far in the literature by any author.

New 3D cone beam CT imaging parameters to assist the dentist in treating patients with Osteogenesis Imperfecta / Messineo, Daniela; Luzzi, Valeria; Pepe, Francesca; Celli, Luca; Turchetti, Arianna; Zambrano, Anna; Celli, Mauro; Polimeni, Antonella; Ierardo, Gaetano. - In: HEALTHCARE. - ISSN 2227-9032. - 8:4(2020), pp. 1-12. [10.3390/healthcare8040546]

New 3D cone beam CT imaging parameters to assist the dentist in treating patients with Osteogenesis Imperfecta

Messineo, Daniela
Primo
;
Luzzi, Valeria
Secondo
;
Pepe, Francesca;Celli, Luca;Turchetti, Arianna;Polimeni, Antonella
Penultimo
;
Ierardo, Gaetano
Ultimo
2020

Abstract

(1) Background: The aim of the work is to identify some imaging parameters in osteogenesis imperfecta to assist the dentist in the diagnosis, planning, and orthodontic treatment of Osteogenesis Imperfecta (OI) using 3D cone beam Computed Tomography (CBCT) and the Double Energy X-ray Absorptiometry (DEXA) technique. (2) Methods: 14 patients (9 males and 5 females; aged mean ± SD 15 ± 1.5) with a clinical-radiological diagnosis of OI were analyzed and divided into mild and moderate to severe forms. The patients’ samples were compared with a control group of 14 patients (8 males and 6 females; aged mean ± SD 15 ± 1.7), free from osteoporotic pathologies. (3) Results: The statistical analysis allowed us to collect four datasets: in the first dataset (C1 sick population vs. C1 healthy population), the t-test showed a p-value < 0.0001; in the second dataset (C2 sick population vs. C2 healthy population), the t-test showed a p-value < 0.0001; in the third dataset (parameter X of the sick population vs. parameter X of the healthy population), the t-test showed a p-value < 0.0001; in the fourth dataset the bone mineralometry (BMD) value detected by the DEXA technique compared to the C2 value of the OI affected population only) the Welch–Satterthwaite test showed a p-value < 0.0001. (4) Conclusions: The research has produced specific imaging parameters that assist the dentist in making diagnostic decisions in OI patients. This study shows that patients with OI have a characteristic chin-bearing symphysis, thinned, and narrowed towards the center, configuring it with a constant “hourglass” appearance, not reported so far in the literature by any author.
2020
CBCT; imperfect osteogenesis; chin; alveolar bone; dentistry
01 Pubblicazione su rivista::01a Articolo in rivista
New 3D cone beam CT imaging parameters to assist the dentist in treating patients with Osteogenesis Imperfecta / Messineo, Daniela; Luzzi, Valeria; Pepe, Francesca; Celli, Luca; Turchetti, Arianna; Zambrano, Anna; Celli, Mauro; Polimeni, Antonella; Ierardo, Gaetano. - In: HEALTHCARE. - ISSN 2227-9032. - 8:4(2020), pp. 1-12. [10.3390/healthcare8040546]
File allegati a questo prodotto
File Dimensione Formato  
Messineo_New-3D-cone-beam_2020.pdf

accesso aperto

Note: https://www.mdpi.com/2227-9032/8/4/546
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 3.38 MB
Formato Adobe PDF
3.38 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1466079
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
social impact