Measurement and control of the dielectric parameters of liquids play a major role in industrial quality-control applications. Although several techniques are currently available to this aim, none of them is simultaneously accurate, cost-effective, and reasonably quick. On the other hand, reflectometry has become a very attractive method for monitoring applications, mostly thanks to its accuracy and flexibility. In this paper, a combined method based on time-domain reflectometry (TDR) and frequency-domain (FD) analysis is presented: the aim is to substantially improve the measurement accuracy of the dielectric parameters of liquids. Starting with typical TDR measurements, the associated FD evaluation of the dielectric parameters is considerably enhanced through the combined effect of the following: 1) specific data-processing techniques; 2) the implementation of a calibration procedure; and 3) the final modeling and minimization routine. Furthermore, to definitively assess the proposed combined procedure, results are compared with measurements directly performed in the FD through a vector network analyzer (VNA). The ultimate goal of the work is to pave the way for the adoption of inexpensive and portable TDR devices in practical industrial monitoring applications.

A Combined TD-FD Method for Enhanced Reflectometry Measurements in Liquid Quality Monitoring / A., Cataldo; L., Catarinucci; L., Tarricone; F., Attivissimo; Piuzzi, Emanuele. - In: IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT. - ISSN 0018-9456. - STAMPA. - 58:10(2009), pp. 3534-3543. [10.1109/tim.2009.2018009]

A Combined TD-FD Method for Enhanced Reflectometry Measurements in Liquid Quality Monitoring

PIUZZI, Emanuele
2009

Abstract

Measurement and control of the dielectric parameters of liquids play a major role in industrial quality-control applications. Although several techniques are currently available to this aim, none of them is simultaneously accurate, cost-effective, and reasonably quick. On the other hand, reflectometry has become a very attractive method for monitoring applications, mostly thanks to its accuracy and flexibility. In this paper, a combined method based on time-domain reflectometry (TDR) and frequency-domain (FD) analysis is presented: the aim is to substantially improve the measurement accuracy of the dielectric parameters of liquids. Starting with typical TDR measurements, the associated FD evaluation of the dielectric parameters is considerably enhanced through the combined effect of the following: 1) specific data-processing techniques; 2) the implementation of a calibration procedure; and 3) the final modeling and minimization routine. Furthermore, to definitively assess the proposed combined procedure, results are compared with measurements directly performed in the FD through a vector network analyzer (VNA). The ultimate goal of the work is to pave the way for the adoption of inexpensive and portable TDR devices in practical industrial monitoring applications.
2009
dielectric measurements; frequency-domain (fd) analysis; microwave reflectometry; quality control; scattering parameters; time-domain reflectometry (tdr)
01 Pubblicazione su rivista::01a Articolo in rivista
A Combined TD-FD Method for Enhanced Reflectometry Measurements in Liquid Quality Monitoring / A., Cataldo; L., Catarinucci; L., Tarricone; F., Attivissimo; Piuzzi, Emanuele. - In: IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT. - ISSN 0018-9456. - STAMPA. - 58:10(2009), pp. 3534-3543. [10.1109/tim.2009.2018009]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/146266
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 34
  • ???jsp.display-item.citation.isi??? 22
social impact