The PADME charged particle detector system should detect positrons and electrons with efficiency better than 99 % and time resolution below 1 ns. The system hosts about 200 readout electronics channels whose operation has to be verified and commissioned. A custom based test system allowing to perform qualitative check of the produced frontend electronics has been developed and was used to test a total of 256 channels. The obtained time resolution was found to be consistent with the requirements and better than 500 ps for all the channels.
Performance of the Front-End Electronics of the PADME charged particle detector system / Georgiev, G.; Ivanov, S.; Kozhuharov, V.; Mitev, M.; Simeonov, R.; Tsankov, L.; Albicocco, P.; Bossi, F.; Buonomo, B.; De Sangro, R.; Domenici, D.; Finocchiaro, G.; Foggetta, L. G.; Ghigo, A.; Gianotti, P.; Piperno, G.; Sarra, I.; Sciascia, B.; Spadaro, T.; Spiriti, E.; Vilucchi, E.; Caricato, A. P.; Gontad, F.; Martino, M.; Oceano, I.; Oliva, F.; Spagnolo, S.; Cesarotti, C.; Frankenthal, A.; Alexander, J.; Chiodini, G.; Ferrarotto, F.; Leonardi, E.; Tehrani, F. S.; Valente, P.; Fiore, S.; Georgiev, G.; Kozhuharov, V.; Liberti, B.; Taruggi, C.; Organtini, G. C.; Raggi, M.; Tsankov, L.; Ivanov, S.; Simeonov, R.; Mitev, M.. - (2018), pp. 1-4. (Intervento presentato al convegno 27th IEEE International Scientific Conference Electronics, ET 2018 tenutosi a Sozopol, Bulgaria) [10.1109/ET.2018.8549581].
Performance of the Front-End Electronics of the PADME charged particle detector system
Kozhuharov V.;Bossi F.;Buonomo B.;Piperno G.;Sciascia B.;Spadaro T.;Vilucchi E.;Valente P.;Fiore S.;Kozhuharov V.;Liberti B.;Organtini G. C.;Raggi M.;
2018
Abstract
The PADME charged particle detector system should detect positrons and electrons with efficiency better than 99 % and time resolution below 1 ns. The system hosts about 200 readout electronics channels whose operation has to be verified and commissioned. A custom based test system allowing to perform qualitative check of the produced frontend electronics has been developed and was used to test a total of 256 channels. The obtained time resolution was found to be consistent with the requirements and better than 500 ps for all the channels.File | Dimensione | Formato | |
---|---|---|---|
Georgiev_Performance of the Front-End Electronics_2018.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
400.38 kB
Formato
Adobe PDF
|
400.38 kB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.