The idea of a railway tunnel under the Bosphorus Strait linking the European and Asian sides of Istanbul was first raised in 1860. Today the project is nearing completion with a design placing the tunnel on the seabed. In this paper the rationale for the tunnel is presented, and the practical problems associated with such a large civil engineering project in a busy urban area considered. Challenges associated with design of the tunnel ventilation system are reviewed, and the implications for tunnel ventilation fan design clarified. The design of three tunnel ventilation fan concepts is presented. First a two-stage counter rotating fan. Second a single-stage high speed fan. Third a two-stage fan with a single motor and impeller on each end of the motor shaft. The relative merits of each concept are considered in detail. The paper concludes with a description of the tunnel ventilation fan installation and maintenance philosophy. The practicality of installing and maintaining tunnel ventilation fans have a primary impact on the on-going ability of the tunnel ventilation fans to operate reliably and therefore on the tunnel's availability. Lessons learnt and implications for on-going best practice are then summarised. Copyright © 2013 by ASME.

Fan conceptual design as applied to the marmaray tunnel ventilation system / Sheard, A. G.; Daneshkhah, K.; Corsini, A.. - 4:(2013). (Intervento presentato al convegno ASME Turbo Expo 2013: Turbine Technical Conference and Exposition, GT 2013 tenutosi a San Antonio, Tx, usa) [10.1115/GT2013-94548].

Fan conceptual design as applied to the marmaray tunnel ventilation system

Corsini A.
2013

Abstract

The idea of a railway tunnel under the Bosphorus Strait linking the European and Asian sides of Istanbul was first raised in 1860. Today the project is nearing completion with a design placing the tunnel on the seabed. In this paper the rationale for the tunnel is presented, and the practical problems associated with such a large civil engineering project in a busy urban area considered. Challenges associated with design of the tunnel ventilation system are reviewed, and the implications for tunnel ventilation fan design clarified. The design of three tunnel ventilation fan concepts is presented. First a two-stage counter rotating fan. Second a single-stage high speed fan. Third a two-stage fan with a single motor and impeller on each end of the motor shaft. The relative merits of each concept are considered in detail. The paper concludes with a description of the tunnel ventilation fan installation and maintenance philosophy. The practicality of installing and maintaining tunnel ventilation fans have a primary impact on the on-going ability of the tunnel ventilation fans to operate reliably and therefore on the tunnel's availability. Lessons learnt and implications for on-going best practice are then summarised. Copyright © 2013 by ASME.
2013
ASME Turbo Expo 2013: Turbine Technical Conference and Exposition, GT 2013
tunnel and metro, Marmaray tunnel, axial fans
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Fan conceptual design as applied to the marmaray tunnel ventilation system / Sheard, A. G.; Daneshkhah, K.; Corsini, A.. - 4:(2013). (Intervento presentato al convegno ASME Turbo Expo 2013: Turbine Technical Conference and Exposition, GT 2013 tenutosi a San Antonio, Tx, usa) [10.1115/GT2013-94548].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1445151
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 0
social impact