The aim of the present study is twofold: to assess ex vivo the role of different lubricants on real-time torque generated during intracanal instrumentation and to check whether two different kinds of torque parameters, operative torque (OT) and average peak torque (APT), could produce similar results. Forty extracted single-rooted teeth were selected for the present study and divided into four equal groups (n = 10): Group A, NaCl 0.2%; Group B, NaOCl 5%; Group C, ethylenediaminetetraacetate (EDTA), and Group D, EDTA and hydrogen peroxide. Afterwards, Edge Taper F2 (Edge Endo, Albuquerque, New Mexico) were rotated clockwise at 300 rpm with 3 Ncm maximum torque by an endodontic torque recording motor. In each sample, mean OT and mean APT were recorded and statistically analyzed with one-way ANOVA and a post hoc Bonferroni between groups (p < 0.05). EDTA (12.11 ± 4.45 Ncm) showed statistically significant (p < 0.05) lower values compared with the other tested irrigant for both parameters. Overall, the two different parameters were both able to differentiate between the influence of lubricants on torsional loads.

Assessment of real-time operative torque during nickel-titanium instrumentation with different lubricants / Mazzoni, A.; Pacifici, A.; Zanza, A.; Del Giudice, A.; Reda, R.; Testarelli, L.; Gambarini, G.; Pacifici, L.. - In: APPLIED SCIENCES. - ISSN 2076-3417. - 10:18(2020), pp. 1-8. [10.3390/app10186201]

Assessment of real-time operative torque during nickel-titanium instrumentation with different lubricants

Pacifici A.
Secondo
Methodology
;
Zanza A.
Data Curation
;
Reda R.
Writing – Review & Editing
;
Testarelli L.
Conceptualization
;
Gambarini G.
Penultimo
Validation
;
Pacifici L.
Ultimo
Supervision
2020

Abstract

The aim of the present study is twofold: to assess ex vivo the role of different lubricants on real-time torque generated during intracanal instrumentation and to check whether two different kinds of torque parameters, operative torque (OT) and average peak torque (APT), could produce similar results. Forty extracted single-rooted teeth were selected for the present study and divided into four equal groups (n = 10): Group A, NaCl 0.2%; Group B, NaOCl 5%; Group C, ethylenediaminetetraacetate (EDTA), and Group D, EDTA and hydrogen peroxide. Afterwards, Edge Taper F2 (Edge Endo, Albuquerque, New Mexico) were rotated clockwise at 300 rpm with 3 Ncm maximum torque by an endodontic torque recording motor. In each sample, mean OT and mean APT were recorded and statistically analyzed with one-way ANOVA and a post hoc Bonferroni between groups (p < 0.05). EDTA (12.11 ± 4.45 Ncm) showed statistically significant (p < 0.05) lower values compared with the other tested irrigant for both parameters. Overall, the two different parameters were both able to differentiate between the influence of lubricants on torsional loads.
2020
endodontics; nickel-titanium; root-canal irrigants; torque
01 Pubblicazione su rivista::01a Articolo in rivista
Assessment of real-time operative torque during nickel-titanium instrumentation with different lubricants / Mazzoni, A.; Pacifici, A.; Zanza, A.; Del Giudice, A.; Reda, R.; Testarelli, L.; Gambarini, G.; Pacifici, L.. - In: APPLIED SCIENCES. - ISSN 2076-3417. - 10:18(2020), pp. 1-8. [10.3390/app10186201]
File allegati a questo prodotto
File Dimensione Formato  
Mazzoni_Assessment_2020.pdf

accesso aperto

Note: https://www.mdpi.com/2076-3417/10/18/6201
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 1.08 MB
Formato Adobe PDF
1.08 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1441576
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 15
social impact