The limited availability of rapid and reliable flow cytometry-based assays for ex vivo quantification of autophagy has hampered their clinical applications for studies of diseases pathogenesis or for the implementation of autophagy-targeting therapies. To this aim, we modified and improved the protocol of a commercial kit developed for quantifying the microtubule-associated protein 1A/1B light chain 3B (LC3), the most reliable marker for autophagosomes currently available. The protocol modifications were set up measuring the autophagic flux in neoplastic (THP-1 cells) and primary cells (peripheral blood mononuclear cells; PBMC) of healthy donors. Moreover, PBMC of active tuberculosis (TB) patients were stimulated with the Mycobacterium tuberculosis purified protein derivatives or infected with live Mycobacterium bovis bacillus Calmette-Guerin (BCG). We found that the baseline median fluorescence intensity (MFI) of THP-1 cells changed depending on the time of sample acquisition to the flow cytometer. To solve this problem, a fixation step was introduced in different stages of the assay’s protocol, obtaining more reproducible and sensitive results when a post-LC3-staining fixation was performed, in either THP-1 cells or PBMC. Furthermore, since we found that results are influenced by the type and the dose of the lysosome inhibitor used, the best dose of Chloroquine for LC3 accumulation were set up in either THP-1 cells or PBMC. Finally, applying these experimental settings, we measured the autophagic flux in CD14+ cells from active TB patients’ PBMC upon BCG infection. In conclusion, our data indicate that the protocol modifications here described improve the stability and accura- cy of a flow cytometry-based assay for the evaluation of autophagy, thus assuring more standardised cell analyses. © the Author(s), 2019.

Optimization of the autophagy measurement in a human cell line and primary cells by flow cytometry / Alonzi, T.; Petruccioli, E.; Vanini, V.; Fimia, G. M.; Goletti, D.. - In: EUROPEAN JOURNAL OF HISTOCHEMISTRY. - ISSN 1121-760X. - 63:2(2019). [10.4081/ejh.2019.3044]

Optimization of the autophagy measurement in a human cell line and primary cells by flow cytometry

Fimia, G. M.;
2019

Abstract

The limited availability of rapid and reliable flow cytometry-based assays for ex vivo quantification of autophagy has hampered their clinical applications for studies of diseases pathogenesis or for the implementation of autophagy-targeting therapies. To this aim, we modified and improved the protocol of a commercial kit developed for quantifying the microtubule-associated protein 1A/1B light chain 3B (LC3), the most reliable marker for autophagosomes currently available. The protocol modifications were set up measuring the autophagic flux in neoplastic (THP-1 cells) and primary cells (peripheral blood mononuclear cells; PBMC) of healthy donors. Moreover, PBMC of active tuberculosis (TB) patients were stimulated with the Mycobacterium tuberculosis purified protein derivatives or infected with live Mycobacterium bovis bacillus Calmette-Guerin (BCG). We found that the baseline median fluorescence intensity (MFI) of THP-1 cells changed depending on the time of sample acquisition to the flow cytometer. To solve this problem, a fixation step was introduced in different stages of the assay’s protocol, obtaining more reproducible and sensitive results when a post-LC3-staining fixation was performed, in either THP-1 cells or PBMC. Furthermore, since we found that results are influenced by the type and the dose of the lysosome inhibitor used, the best dose of Chloroquine for LC3 accumulation were set up in either THP-1 cells or PBMC. Finally, applying these experimental settings, we measured the autophagic flux in CD14+ cells from active TB patients’ PBMC upon BCG infection. In conclusion, our data indicate that the protocol modifications here described improve the stability and accura- cy of a flow cytometry-based assay for the evaluation of autophagy, thus assuring more standardised cell analyses. © the Author(s), 2019.
2019
bacterial protein; chloroquine; MAP1LC3B protein, human; microtubule associated protein, autophagy; chemistry; drug effect; flow cytometry; fluorescence; human; microbiology; mononuclear cell; Mycobacterium bovis; procedures; staining; THP-1 cell line, Autophagy; Bacterial Proteins; Chloroquine; Flow Cytometry; Fluorescence; Humans; Leukocytes, Mononuclear; Microtubule-Associated Proteins; Mycobacterium bovis; Staining and Labeling; THP-1 Cells; Autophagy; BCG; Flow cytometry; LC3; PBMC; THP-1; Tuberculosis
01 Pubblicazione su rivista::01a Articolo in rivista
Optimization of the autophagy measurement in a human cell line and primary cells by flow cytometry / Alonzi, T.; Petruccioli, E.; Vanini, V.; Fimia, G. M.; Goletti, D.. - In: EUROPEAN JOURNAL OF HISTOCHEMISTRY. - ISSN 1121-760X. - 63:2(2019). [10.4081/ejh.2019.3044]
File allegati a questo prodotto
File Dimensione Formato  
Alonzi_Optimization_2019.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 868.27 kB
Formato Adobe PDF
868.27 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1411303
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 7
social impact