We study the electromagnetic coupling of the Advanced Virgo (AdV) input mirror payload in response to a slowly time-varying magnetic field. As the problem is not amenable to analytical solution, we employ and validate a finite element (FE) analysis approach. The FE model is built to represent as faithfully as possible the real object, and it has been validated by comparison with experimental measurements. The intent is to estimate the induced currents and the magnetic field in the neighbourhood of the payload. The procedure found 21 equivalent electrical configurations that are compatible with the measurements. These have been used to compute the magnetic noise contribution to the total AdV strain noise. At the current stage of development, AdV seems to be unaffected by magnetic noise, but we foresee a non-negligible coupling once AdV reaches the design sensitivity.

Magnetic coupling to the advanced Virgo payloads and its impact on the low frequency sensitivity / Cirone, A.; Chincarini, A.; Neri, M.; Farinon, S.; Gemme, G.; Fiori, I.; Paoletti, F.; Majorana, E.; Puppo, P.; Rapagnani, P.; Ruggi, P.; Swinkels, B. L.. - In: REVIEW OF SCIENTIFIC INSTRUMENTS. - ISSN 0034-6748. - 89:11(2018), p. 114501. [10.1063/1.5045397]

Magnetic coupling to the advanced Virgo payloads and its impact on the low frequency sensitivity

Majorana E.;Rapagnani P.;
2018

Abstract

We study the electromagnetic coupling of the Advanced Virgo (AdV) input mirror payload in response to a slowly time-varying magnetic field. As the problem is not amenable to analytical solution, we employ and validate a finite element (FE) analysis approach. The FE model is built to represent as faithfully as possible the real object, and it has been validated by comparison with experimental measurements. The intent is to estimate the induced currents and the magnetic field in the neighbourhood of the payload. The procedure found 21 equivalent electrical configurations that are compatible with the measurements. These have been used to compute the magnetic noise contribution to the total AdV strain noise. At the current stage of development, AdV seems to be unaffected by magnetic noise, but we foresee a non-negligible coupling once AdV reaches the design sensitivity.
2018
Actuators Payload; GW detectors; Advanced Virgo; electromagnetic coupling
01 Pubblicazione su rivista::01a Articolo in rivista
Magnetic coupling to the advanced Virgo payloads and its impact on the low frequency sensitivity / Cirone, A.; Chincarini, A.; Neri, M.; Farinon, S.; Gemme, G.; Fiori, I.; Paoletti, F.; Majorana, E.; Puppo, P.; Rapagnani, P.; Ruggi, P.; Swinkels, B. L.. - In: REVIEW OF SCIENTIFIC INSTRUMENTS. - ISSN 0034-6748. - 89:11(2018), p. 114501. [10.1063/1.5045397]
File allegati a questo prodotto
File Dimensione Formato  
Majorana_Magnetic-coupling_2018.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 10.11 MB
Formato Adobe PDF
10.11 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.