The post-earthquake inspections for the assessment of buildings’ usability have a key role in the post-earthquake emergency phases. In particular, a primary importance is given to the damage and usability assessment of public buildings, which is crucial for a quick recovery of the social activity. A significant contribution in the usability evaluation of such buildings (i.e. schools, hospitals, strategic infrastructures and historical and monumental heritage buildings) and churches was given by the ReLUIS-Laboratories University Network of seismic engineering-consortium, a competence centre of the Civil Protection Department, in the post-earthquake emergency phase of the recent central Italy earthquake. The in-situ surveys were carried out by teams of surveyors made up of experts from a list of ReLUIS researchers mobilized in accordance with emergency procedures in case of earthquake. The seismic sequence involved four significant events: M6.0 August 24, M5.9 October 26, M6.5 October 30, and M 5.5 January 18; thus several inspections were also repeated in order to evaluate the cumulative effects of seismic actions on the damage to constructions. The results of ReLUIS activities are herein presented and discussed.

Usability and damage assessment of public buildings and churches after the 2016 central italy earthquake: The reluis experience / Di Ludovico, M.; De Martino, G.; Santoro, A.; Prota, A.; Manfredi, G.; Calderini, C.; Carocci, C.; da Porto, F.; Dall'asta, A.; De Santis, S.; Fiorentino, G.; Digrisolo, A.; Dolce, M.; Moroni, C.; Ferracuti, B.; Ferretti, D.; Graziotti, F.; Penna, A.; Mannella, A.; Marini, A.; Mazzotti, C.; Sorrentino, L.. - (2019), pp. 915-924. (Intervento presentato al convegno 7th International Conference on Earthquake Geotechnical Engineering, ICEGE 2019 tenutosi a ita).

Usability and damage assessment of public buildings and churches after the 2016 central italy earthquake: The reluis experience

Sorrentino L.
2019

Abstract

The post-earthquake inspections for the assessment of buildings’ usability have a key role in the post-earthquake emergency phases. In particular, a primary importance is given to the damage and usability assessment of public buildings, which is crucial for a quick recovery of the social activity. A significant contribution in the usability evaluation of such buildings (i.e. schools, hospitals, strategic infrastructures and historical and monumental heritage buildings) and churches was given by the ReLUIS-Laboratories University Network of seismic engineering-consortium, a competence centre of the Civil Protection Department, in the post-earthquake emergency phase of the recent central Italy earthquake. The in-situ surveys were carried out by teams of surveyors made up of experts from a list of ReLUIS researchers mobilized in accordance with emergency procedures in case of earthquake. The seismic sequence involved four significant events: M6.0 August 24, M5.9 October 26, M6.5 October 30, and M 5.5 January 18; thus several inspections were also repeated in order to evaluate the cumulative effects of seismic actions on the damage to constructions. The results of ReLUIS activities are herein presented and discussed.
2019
7th International Conference on Earthquake Geotechnical Engineering, ICEGE 2019
Central Italy seismic sequence; Historical and monumental heritage buildings; ReLUIS; School buildings; Usability and damage assessment
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Usability and damage assessment of public buildings and churches after the 2016 central italy earthquake: The reluis experience / Di Ludovico, M.; De Martino, G.; Santoro, A.; Prota, A.; Manfredi, G.; Calderini, C.; Carocci, C.; da Porto, F.; Dall'asta, A.; De Santis, S.; Fiorentino, G.; Digrisolo, A.; Dolce, M.; Moroni, C.; Ferracuti, B.; Ferretti, D.; Graziotti, F.; Penna, A.; Mannella, A.; Marini, A.; Mazzotti, C.; Sorrentino, L.. - (2019), pp. 915-924. (Intervento presentato al convegno 7th International Conference on Earthquake Geotechnical Engineering, ICEGE 2019 tenutosi a ita).
File allegati a questo prodotto
File Dimensione Formato  
Diludovico_Usability_2019.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 514.36 kB
Formato Adobe PDF
514.36 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1408388
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 2
social impact