Enzymes immobilisation represents a critical issue in the design of biosensors to achieve standardization as well as suitable analytical performances in terms of sensitivity, selectivity, and stability. In this work electrospray deposition (ESD) has been exploited as a novel technique for the immobilisation of laccase enzyme on carbon black modified screen-printed electrodes. The aim is to fabricate an amperometric biosensor for phenolic compound detection. The electrodes produced by ESD have been analysed by scanning electron microscopy and characterised electrochemically to prove that this immobilisation technique is suited to manufacture high performance biosensors. The results show that the laccase enzyme maintains its activity after undergoing the electrospray ionisation process and deposition and the fabricated biosensor has improved performances in terms of storage (up to 3 months at room temperature) and working (up to 25 measurements on the same electrode) stability. The laccase-based biosensor has been tested for phenolic compound detection, with catechol as target analyte, in the linear range 2.5–50 μM, with 2.0 μM limit of detection, without interference from lead, cadmium, atrazine, and paraoxon, and without matrix effect in drinking, surface, and wastewater.

Electrospray deposition as a smart technique for laccase immobilisation on carbon black-nanomodified screen-printed electrodes / Castrovilli, Mattea Carmen; Bolognesi, Paola; Chiarinelli, Jacopo; Avaldi, Lorenzo; Cartoni, Antonella; Calandra, Pietro; Tempesta, Emanuela; Giardi, Maria Teresa; Antonacci, Amina; Arduini, Fabiana; Scognamiglio, Viviana. - In: BIOSENSORS & BIOELECTRONICS. - ISSN 0956-5663. - 163:(2020), pp. 1-7. [10.1016/j.bios.2020.112299]

Electrospray deposition as a smart technique for laccase immobilisation on carbon black-nanomodified screen-printed electrodes

Cartoni, Antonella;
2020

Abstract

Enzymes immobilisation represents a critical issue in the design of biosensors to achieve standardization as well as suitable analytical performances in terms of sensitivity, selectivity, and stability. In this work electrospray deposition (ESD) has been exploited as a novel technique for the immobilisation of laccase enzyme on carbon black modified screen-printed electrodes. The aim is to fabricate an amperometric biosensor for phenolic compound detection. The electrodes produced by ESD have been analysed by scanning electron microscopy and characterised electrochemically to prove that this immobilisation technique is suited to manufacture high performance biosensors. The results show that the laccase enzyme maintains its activity after undergoing the electrospray ionisation process and deposition and the fabricated biosensor has improved performances in terms of storage (up to 3 months at room temperature) and working (up to 25 measurements on the same electrode) stability. The laccase-based biosensor has been tested for phenolic compound detection, with catechol as target analyte, in the linear range 2.5–50 μM, with 2.0 μM limit of detection, without interference from lead, cadmium, atrazine, and paraoxon, and without matrix effect in drinking, surface, and wastewater.
2020
electrospray deposition; laccase enzyme; carbon black; screen-printed electrodes
01 Pubblicazione su rivista::01a Articolo in rivista
Electrospray deposition as a smart technique for laccase immobilisation on carbon black-nanomodified screen-printed electrodes / Castrovilli, Mattea Carmen; Bolognesi, Paola; Chiarinelli, Jacopo; Avaldi, Lorenzo; Cartoni, Antonella; Calandra, Pietro; Tempesta, Emanuela; Giardi, Maria Teresa; Antonacci, Amina; Arduini, Fabiana; Scognamiglio, Viviana. - In: BIOSENSORS & BIOELECTRONICS. - ISSN 0956-5663. - 163:(2020), pp. 1-7. [10.1016/j.bios.2020.112299]
File allegati a questo prodotto
File Dimensione Formato  
Castrovilli_Electrospray_2020.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.31 MB
Formato Adobe PDF
1.31 MB Adobe PDF   Contatta l'autore
Castrovilli_postprint_Electrospray_2020.pdf

accesso aperto

Note: postprint
Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Creative commons
Dimensione 737.02 kB
Formato Adobe PDF
737.02 kB Adobe PDF
Castrovilli_supporting_Electrospray_2020.pdf

solo gestori archivio

Note: supporting material
Tipologia: Altro materiale allegato
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 27.28 kB
Formato Adobe PDF
27.28 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1406330
Citazioni
  • ???jsp.display-item.citation.pmc??? 12
  • Scopus 41
  • ???jsp.display-item.citation.isi??? 35
social impact