New-generation devices such as Evolut and Portico have provided favorable results in patients who underwent transcatheter aortic valve implantation (TAVI) for aortic stenosis, but their comparative effectiveness remains debated, despite its relevance when envisioning TAVI in low-risk patients. We evaluated the safety and efficacy of 2 leading TAVI devices (Evolut and Portico) used by the same team of experienced TAVI operators, focusing on long-term outcomes, including major adverse events (i.e., the composite of death, stroke, myocardial infarction, major vascular complication, or major bleeding). Unadjusted and propensity score-adjusted analyses were carried out. A total of 233 patients were included, 119 (51.1%) receiving Evolut and 114 (49%) Portico. Baseline and procedural data showed significant between-device differences, including functional class, surgical risk, chronic obstructive pulmonary disease, renal function, transesophageal guidance, device size, postdilation, and procedural time (all p <0.05). Yet, acute and in-hospital outcomes were not significantly different (all p >0.05). Follow-up status was ascertained in 228 (98%) patients after 15.0 ± 7.6 months. Unadjusted analysis showed similar rates of major adverse events, as well as the individual risk of death, stroke, myocardial infarction, major vascular complication, major bleeding, and pacemaker implantation (all p >0.05). Even at propensity score-adjusted analysis outcomes were not significantly different with Evolut and Portico (all p >0.05). In conclusion, Evolut and Portico devices yield similarly favorable results at long-term follow-up when used by experienced TAVI operators.

Long-term follow-up of transcatheter aortic valve implantation with portico versus evolut devices / Corcione, N.; Biondi-Zoccai, G.; Ferraro, P.; Morello, A.; Conte, S.; Cimmino, M.; Vigna, C.; Frati, G.; De Persio, G.; Altamura, L.; Tomai, F.; Berni, A.; Cassese, M.; Pepe, M.; Giordano, A.. - In: THE AMERICAN JOURNAL OF CARDIOLOGY. - ISSN 0002-9149. - 125:8(2020), pp. 1209-1215. [10.1016/j.amjcard.2020.01.018]

Long-term follow-up of transcatheter aortic valve implantation with portico versus evolut devices

Biondi-Zoccai G.;Morello A.;Frati G.;Tomai F.;Berni A.;Cassese M.;
2020

Abstract

New-generation devices such as Evolut and Portico have provided favorable results in patients who underwent transcatheter aortic valve implantation (TAVI) for aortic stenosis, but their comparative effectiveness remains debated, despite its relevance when envisioning TAVI in low-risk patients. We evaluated the safety and efficacy of 2 leading TAVI devices (Evolut and Portico) used by the same team of experienced TAVI operators, focusing on long-term outcomes, including major adverse events (i.e., the composite of death, stroke, myocardial infarction, major vascular complication, or major bleeding). Unadjusted and propensity score-adjusted analyses were carried out. A total of 233 patients were included, 119 (51.1%) receiving Evolut and 114 (49%) Portico. Baseline and procedural data showed significant between-device differences, including functional class, surgical risk, chronic obstructive pulmonary disease, renal function, transesophageal guidance, device size, postdilation, and procedural time (all p <0.05). Yet, acute and in-hospital outcomes were not significantly different (all p >0.05). Follow-up status was ascertained in 228 (98%) patients after 15.0 ± 7.6 months. Unadjusted analysis showed similar rates of major adverse events, as well as the individual risk of death, stroke, myocardial infarction, major vascular complication, major bleeding, and pacemaker implantation (all p >0.05). Even at propensity score-adjusted analysis outcomes were not significantly different with Evolut and Portico (all p >0.05). In conclusion, Evolut and Portico devices yield similarly favorable results at long-term follow-up when used by experienced TAVI operators.
2020
valvular disease; propensity score; tavi; replacement
01 Pubblicazione su rivista::01a Articolo in rivista
Long-term follow-up of transcatheter aortic valve implantation with portico versus evolut devices / Corcione, N.; Biondi-Zoccai, G.; Ferraro, P.; Morello, A.; Conte, S.; Cimmino, M.; Vigna, C.; Frati, G.; De Persio, G.; Altamura, L.; Tomai, F.; Berni, A.; Cassese, M.; Pepe, M.; Giordano, A.. - In: THE AMERICAN JOURNAL OF CARDIOLOGY. - ISSN 0002-9149. - 125:8(2020), pp. 1209-1215. [10.1016/j.amjcard.2020.01.018]
File allegati a questo prodotto
File Dimensione Formato  
Corcione_Long-term_2020.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 771.43 kB
Formato Adobe PDF
771.43 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1401906
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 8
social impact