Objectives: We sought to analyze the collected worldwide experience with use of snorkel/chimney endovascular aneurysm repair (EVAR) for complex abdominal aneurysm treatment. Background: EVAR has largely replaced open surgery worldwide for anatomically suitable aortic aneurysms. Lack of availability of fenestrated and branched devices has encouraged an alternative strategy utilizing parallel or snorkel/chimney grafts (ch-EVAR). Methods: Clinical and radiographic information was retrospectively reviewed and analyzed on 517 patients treated by ch-EVAR from 2008 from 2014 by prearranged defined and documented protocols. Results: A total of 119 patients in US centers and 398 in European centers were treated during the study period. US centers preferentially used Zenith stent-grafts (54.2%) and European centers Endurant stent-grafts (62.2%) for the main body component. Overall 898 chimney grafts (49.2% balloon expandable, 39.6% self-expanding covered stents, and 11.2% balloon expandable bare metal stents) were placed in 692 renal arteries, 156 superior mesenteric arteries (SMA), and 50 celiac arteries. At a mean follow-up of 17.1 months (range: 1-70 months), primary patency was 94%, with secondary patency of 95.3%. Overall survival of patients in this high-risk cohort for open repair at latest follow-up was 79%. Conclusions: This global experience represents the largest series in the ch-EVAR literature and demonstrates comparable outcomes to those in published reports of branched/fenestrated devices, suggesting the appropriateness of broader applicability and the need for continued careful surveillance. These results support ch-EVAR as a valid off-the-shelf and immediately available alternative in the treatment of complex abdominal EVAR and provide impetus for the standardization of these techniques in the future.

Collected world experience about the performance of the snorkel/chimney endovascular technique in the treatment of complex aortic pathologies: The PERICLES registry / Donas, K. P.; Lee, J. T.; Lachat, M.; Torsello, G.; Veith, F. J.; Dalman, R. L.; Tran, K.; Pecoraro, F.; Bisdas, T.; Seifert, S.; Esche, M.; Gasparini, D.; Frigatti, P.; Adovasio, R.; Mucelli, F. P.; Damrauer, S. M.; Woo, E. Y.; Beck, A.; Scali, S.; Minion, D.; Salenius, J.; Suominen, V.; Mangialardi, N.; Ronchey, S.; Fazzini, S.; Mestres, G.; Riambau, V.; Mosquera, N. J.. - In: ANNALS OF SURGERY. - ISSN 0003-4932. - 262:3(2015), pp. 546-552. (Intervento presentato al convegno 135th ASA Annual Meeting tenutosi a San Diego, CA) [10.1097/SLA.0000000000001405].

Collected world experience about the performance of the snorkel/chimney endovascular technique in the treatment of complex aortic pathologies: The PERICLES registry

Fazzini S.;
2015

Abstract

Objectives: We sought to analyze the collected worldwide experience with use of snorkel/chimney endovascular aneurysm repair (EVAR) for complex abdominal aneurysm treatment. Background: EVAR has largely replaced open surgery worldwide for anatomically suitable aortic aneurysms. Lack of availability of fenestrated and branched devices has encouraged an alternative strategy utilizing parallel or snorkel/chimney grafts (ch-EVAR). Methods: Clinical and radiographic information was retrospectively reviewed and analyzed on 517 patients treated by ch-EVAR from 2008 from 2014 by prearranged defined and documented protocols. Results: A total of 119 patients in US centers and 398 in European centers were treated during the study period. US centers preferentially used Zenith stent-grafts (54.2%) and European centers Endurant stent-grafts (62.2%) for the main body component. Overall 898 chimney grafts (49.2% balloon expandable, 39.6% self-expanding covered stents, and 11.2% balloon expandable bare metal stents) were placed in 692 renal arteries, 156 superior mesenteric arteries (SMA), and 50 celiac arteries. At a mean follow-up of 17.1 months (range: 1-70 months), primary patency was 94%, with secondary patency of 95.3%. Overall survival of patients in this high-risk cohort for open repair at latest follow-up was 79%. Conclusions: This global experience represents the largest series in the ch-EVAR literature and demonstrates comparable outcomes to those in published reports of branched/fenestrated devices, suggesting the appropriateness of broader applicability and the need for continued careful surveillance. These results support ch-EVAR as a valid off-the-shelf and immediately available alternative in the treatment of complex abdominal EVAR and provide impetus for the standardization of these techniques in the future.
2015
135th ASA Annual Meeting
Abdominal aortic aneurysm; Endovascular; Fenestrated; Thoracoabdominal; Vascular; Aortic Aneurysm, Abdominal; Aortography; Blood Vessel Prosthesis Implantation; Endovascular Procedures; Europe; Female; Follow-Up Studies; Global Health; Humans; Kaplan-Meier Estimate; Male; Prosthesis Design; Prosthesis Failure; Retrospective Studies; Risk Assessment; Severity of Illness Index; Stents; Survival Rate; Treatment Outcome; United States; Blood Vessel Prosthesis; Registries
04 Pubblicazione in atti di convegno::04c Atto di convegno in rivista
Collected world experience about the performance of the snorkel/chimney endovascular technique in the treatment of complex aortic pathologies: The PERICLES registry / Donas, K. P.; Lee, J. T.; Lachat, M.; Torsello, G.; Veith, F. J.; Dalman, R. L.; Tran, K.; Pecoraro, F.; Bisdas, T.; Seifert, S.; Esche, M.; Gasparini, D.; Frigatti, P.; Adovasio, R.; Mucelli, F. P.; Damrauer, S. M.; Woo, E. Y.; Beck, A.; Scali, S.; Minion, D.; Salenius, J.; Suominen, V.; Mangialardi, N.; Ronchey, S.; Fazzini, S.; Mestres, G.; Riambau, V.; Mosquera, N. J.. - In: ANNALS OF SURGERY. - ISSN 0003-4932. - 262:3(2015), pp. 546-552. (Intervento presentato al convegno 135th ASA Annual Meeting tenutosi a San Diego, CA) [10.1097/SLA.0000000000001405].
File allegati a questo prodotto
File Dimensione Formato  
Donas_Snorkel-chimney-endovascular_2015.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 254.26 kB
Formato Adobe PDF
254.26 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1401168
Citazioni
  • ???jsp.display-item.citation.pmc??? 31
  • Scopus 259
  • ???jsp.display-item.citation.isi??? 226
social impact