Arrhythmia Detection in Single- and Dual-Chamber ICDs. The implantable cardioverter de- fibrillator (ICD) offers life-saving therapies for primary and secondary prevention of sudden cardiac death in high-risk patients. However, ICD detection algorithms consistently misclassify a substantial proportion of supraventricular rhythms, thus carrying the risk for inappropriate therapies. Although single-chamber ICD (Sc-ICD) discrimination tools have been reported to provide high specificity in rejecting sinus tachy- cardia and atrial fibrillation with a relatively low ventricular rate, accurate recognition of atrial fibrillation with faster ventricular rates, atrial tachycardias, atrial flutter, and some reentrant tachycardias is still an issue. Dual-chamber ICDs (Dc-ICDs) are supposed to overcome specificity issues by enhancing detection al- gorithms with information derived from the atrial and ventricular timing relationship. The initial promise of Dc-ICDs was to improve detection specificity without compromising sensitivity, and to translate this advantage over Sc-ICDs in a more selective use of aggressive therapies. Despite this solid background, su- periority of Dc- over Sc-ICDs has never been convincingly demonstrated. The present review focuses on the efficacy of contemporary ICD arrhythmia discrimination tools and appraises the so far reported evidence supporting the superiority of Dc-ICDs in preventing inappropriate therapies.

Arrhythmia Detection in Single and Dual Chamber Implantable Cardioverter Defibrillators: The More Leads, the Better? / Francia, Pietro; Balla, Cristina; Uccellini, A; Cappato, R.. - In: JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY. - ISSN 1045-3873. - STAMPA. - 20 (9):(2009), pp. 1077-1082. [10.1111/j.1540-8167.2009.01477.x]

Arrhythmia Detection in Single and Dual Chamber Implantable Cardioverter Defibrillators: The More Leads, the Better?

FRANCIA, Pietro;BALLA, CRISTINA;
2009

Abstract

Arrhythmia Detection in Single- and Dual-Chamber ICDs. The implantable cardioverter de- fibrillator (ICD) offers life-saving therapies for primary and secondary prevention of sudden cardiac death in high-risk patients. However, ICD detection algorithms consistently misclassify a substantial proportion of supraventricular rhythms, thus carrying the risk for inappropriate therapies. Although single-chamber ICD (Sc-ICD) discrimination tools have been reported to provide high specificity in rejecting sinus tachy- cardia and atrial fibrillation with a relatively low ventricular rate, accurate recognition of atrial fibrillation with faster ventricular rates, atrial tachycardias, atrial flutter, and some reentrant tachycardias is still an issue. Dual-chamber ICDs (Dc-ICDs) are supposed to overcome specificity issues by enhancing detection al- gorithms with information derived from the atrial and ventricular timing relationship. The initial promise of Dc-ICDs was to improve detection specificity without compromising sensitivity, and to translate this advantage over Sc-ICDs in a more selective use of aggressive therapies. Despite this solid background, su- periority of Dc- over Sc-ICDs has never been convincingly demonstrated. The present review focuses on the efficacy of contemporary ICD arrhythmia discrimination tools and appraises the so far reported evidence supporting the superiority of Dc-ICDs in preventing inappropriate therapies.
2009
01 Pubblicazione su rivista::01a Articolo in rivista
Arrhythmia Detection in Single and Dual Chamber Implantable Cardioverter Defibrillators: The More Leads, the Better? / Francia, Pietro; Balla, Cristina; Uccellini, A; Cappato, R.. - In: JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY. - ISSN 1045-3873. - STAMPA. - 20 (9):(2009), pp. 1077-1082. [10.1111/j.1540-8167.2009.01477.x]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/139718
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 22
social impact