Peri-implant disease may affect survival of dental implants. The aim of the study is to analyze the effectiveness of diode laser as a supportive modality to the non-surgical conventional treatment of peri-implant mucositis (PiM) and initial peri-implantitis (PI). Twenty-three patients with single implants suffering from PiM or initial PI were selected and randomly divided into two groups; control group (CG) received non-surgical conventional treatment, and test group (TG) received non-surgical conventional treatment and diode laser application with wavelength of 980 nm. Probing pocket depth (PPD) and bleeding on probing (BOP) were recorded at baseline (T0) and at 3 months follow-up (T1). The average of PPD value for TG was 4.04 ± 0.54 mm at T0 and it was 2.98 ± 0.70 mm at T1. In the CG, PPD average was 3.8 ± 1.24 mm at T0 and was 3.54 ± 0.35 mm at T1. In TG, the BOP was positive in 44 sites at T0 and in 6 sites at T1. In CG, the BOP was positively observed in 52 sites at T0 and in 28 sites at T1. The 980-nm diode laser may be considered an adjunct to the conventional non-surgical treatments of PiM and initial PI.
Evaluation of adjunctive efficacy of diode laser in the treatment of peri-implant mucositis: a randomized clinical trial / Tenore, Gianluca; Montori, Alessandra; Mohsen, AHMED AMIR MOHAMED; Mattarelli, Giovanni; Palaia, Gaspare; Romeo, Umberto. - In: LASERS IN MEDICAL SCIENCE. - ISSN 0268-8921. - 35:6(2020), pp. 1411-1417. [10.1007/s10103-020-03009-y]
Evaluation of adjunctive efficacy of diode laser in the treatment of peri-implant mucositis: a randomized clinical trial
Gianluca TenorePrimo
;Ahmed Mohsen
;Gaspare PalaiaPenultimo
;Umberto RomeoUltimo
2020
Abstract
Peri-implant disease may affect survival of dental implants. The aim of the study is to analyze the effectiveness of diode laser as a supportive modality to the non-surgical conventional treatment of peri-implant mucositis (PiM) and initial peri-implantitis (PI). Twenty-three patients with single implants suffering from PiM or initial PI were selected and randomly divided into two groups; control group (CG) received non-surgical conventional treatment, and test group (TG) received non-surgical conventional treatment and diode laser application with wavelength of 980 nm. Probing pocket depth (PPD) and bleeding on probing (BOP) were recorded at baseline (T0) and at 3 months follow-up (T1). The average of PPD value for TG was 4.04 ± 0.54 mm at T0 and it was 2.98 ± 0.70 mm at T1. In the CG, PPD average was 3.8 ± 1.24 mm at T0 and was 3.54 ± 0.35 mm at T1. In TG, the BOP was positive in 44 sites at T0 and in 6 sites at T1. In CG, the BOP was positively observed in 52 sites at T0 and in 28 sites at T1. The 980-nm diode laser may be considered an adjunct to the conventional non-surgical treatments of PiM and initial PI.File | Dimensione | Formato | |
---|---|---|---|
Tenore_Evaluation_2020.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
552.67 kB
Formato
Adobe PDF
|
552.67 kB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.