Background: The subcutaneous implantable cardioverter defibrillator (S-ICD) is a relatively novel alternative to the transvenous ICD for the treatment of life-threatening ventricular arrhythmias, and is currently used in the clinical practice of several centers. The aim of this analysis was to describe current Italian practice regarding S-ICD implantation and its evolution over the years. Methods: We analyzed 607 consecutive patients (78% male, 48 ± 16 years) who underwent S-ICD implantation in 39 Italian centers from 2013 to 2017. Results: Structural cardiomyopathy was present in 78% of patients and 30% of patients received their device for secondary prevention. The proportion of patients with dilated cardiomyopathy and with left ventricular ejection fraction ≤35% increased from ≤2014 to 2017 (from 38% to 58%, from 33% to 53%, respectively; both p < 0.05). Almost all procedures (97%) were performed in electrophysiology laboratories. Over the last 4 years, the 2-incision implantation technique has been widely adopted, with sub- or inter-muscular positioning of the generator, under local anesthesia or deep sedation (≤2014 versus 2017: all p < 0.001). Defibrillation testing was performed in 81% of patients. Shock energy of ≤65 J was successful in 93.9% of patients and the overall cardioversion success rate at ≤80 J was 99.8%. Conclusions: Our analysis confirmed that the S-ICD continues to be preferentially used in specific patients (younger, less frequently with dilated cardiomyopathy and low ejection fraction.). Nonetheless, we noted a trend toward the wider use of S-ICD in patients with dilated cardiomyopathy and systolic dysfunction over the years. Novel approaches have been adopted while the acute efficacy of the system has remained stably high.

Subcutaneous implantable cardioverter defibrillator implantation. An analysis of Italian clinical practice and its evolution / D'Onofrio, A.; Pieragnoli, P.; Biffi, M.; Nigro, G.; Migliore, F.; Francia, P.; De Filippo, P.; Capucci, A.; Botto, G. L.; Giammaria, M.; Palmisano, P.; Pisano, E.; Bisignani, G.; La Greca, C.; Sarubbi, B.; Sala, S.; Viscusi, M.; Landolina, M.; Lovecchio, M.; Valsecchi, S.; Bongiorni, M. G.. - In: INTERNATIONAL JOURNAL OF CARDIOLOGY. - ISSN 0167-5273. - 272:Dec 1(2018), pp. 162-167. [10.1016/j.ijcard.2018.07.139]

Subcutaneous implantable cardioverter defibrillator implantation. An analysis of Italian clinical practice and its evolution

Francia P.;
2018

Abstract

Background: The subcutaneous implantable cardioverter defibrillator (S-ICD) is a relatively novel alternative to the transvenous ICD for the treatment of life-threatening ventricular arrhythmias, and is currently used in the clinical practice of several centers. The aim of this analysis was to describe current Italian practice regarding S-ICD implantation and its evolution over the years. Methods: We analyzed 607 consecutive patients (78% male, 48 ± 16 years) who underwent S-ICD implantation in 39 Italian centers from 2013 to 2017. Results: Structural cardiomyopathy was present in 78% of patients and 30% of patients received their device for secondary prevention. The proportion of patients with dilated cardiomyopathy and with left ventricular ejection fraction ≤35% increased from ≤2014 to 2017 (from 38% to 58%, from 33% to 53%, respectively; both p < 0.05). Almost all procedures (97%) were performed in electrophysiology laboratories. Over the last 4 years, the 2-incision implantation technique has been widely adopted, with sub- or inter-muscular positioning of the generator, under local anesthesia or deep sedation (≤2014 versus 2017: all p < 0.001). Defibrillation testing was performed in 81% of patients. Shock energy of ≤65 J was successful in 93.9% of patients and the overall cardioversion success rate at ≤80 J was 99.8%. Conclusions: Our analysis confirmed that the S-ICD continues to be preferentially used in specific patients (younger, less frequently with dilated cardiomyopathy and low ejection fraction.). Nonetheless, we noted a trend toward the wider use of S-ICD in patients with dilated cardiomyopathy and systolic dysfunction over the years. Novel approaches have been adopted while the acute efficacy of the system has remained stably high.
2018
defibrillation test; implantable defibrillator; subcutaneous; adult; arrhythmias, cardiac; defibrillators; implantable; electrocardiography; female; humans; italy; male; middle aged; registries; treatment outcome; subcutaneous tissue
01 Pubblicazione su rivista::01g Articolo di rassegna (Review)
Subcutaneous implantable cardioverter defibrillator implantation. An analysis of Italian clinical practice and its evolution / D'Onofrio, A.; Pieragnoli, P.; Biffi, M.; Nigro, G.; Migliore, F.; Francia, P.; De Filippo, P.; Capucci, A.; Botto, G. L.; Giammaria, M.; Palmisano, P.; Pisano, E.; Bisignani, G.; La Greca, C.; Sarubbi, B.; Sala, S.; Viscusi, M.; Landolina, M.; Lovecchio, M.; Valsecchi, S.; Bongiorni, M. G.. - In: INTERNATIONAL JOURNAL OF CARDIOLOGY. - ISSN 0167-5273. - 272:Dec 1(2018), pp. 162-167. [10.1016/j.ijcard.2018.07.139]
File allegati a questo prodotto
File Dimensione Formato  
D'Onofrio_Subcutaneous_2018.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 914.86 kB
Formato Adobe PDF
914.86 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1386296
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 28