The paper reports a complete study of electrical power system on a metro line under construction in Buenos Aires supplied at 2x25 kV-50 HZ. The metro line, is at the forefront from the technological point of view, because of it represents one of the very few examples of a metro line with a 2x25 kV alternating current electrification system.The results of traffic and electrical simulations of the proposed 2x25 kV-50 Hz electrical system are presented, including energy performance due to the braking recovery, considering time shifting of departures.Different network operations, have been taken into account considering the out of service of main electrical substation. Electrical standard requirements have been taken into account to verified the results performed.Overloads of electrical machines, voltage values on the pantograph, step and touch voltages and voltage unbalances have been calculated.

A high traffic density metro electrfied at 2x25 kV 50 Hz / Lamedica, R.; Midili, A.; Ruvio, A.; Guidi Buffarini, G.; Carones, N.; Laurini, M.. - (2019), pp. 1-6. (Intervento presentato al convegno 19th IEEE International conference on environment and electrical engineering and 2019 IEEE industrial and commercial power systems europe, EEEIC/I and CPS Europe 2019 tenutosi a Genoa; Italy) [10.1109/EEEIC.2019.8783848].

A high traffic density metro electrfied at 2x25 kV 50 Hz

Lamedica R.;Ruvio A.;
2019

Abstract

The paper reports a complete study of electrical power system on a metro line under construction in Buenos Aires supplied at 2x25 kV-50 HZ. The metro line, is at the forefront from the technological point of view, because of it represents one of the very few examples of a metro line with a 2x25 kV alternating current electrification system.The results of traffic and electrical simulations of the proposed 2x25 kV-50 Hz electrical system are presented, including energy performance due to the braking recovery, considering time shifting of departures.Different network operations, have been taken into account considering the out of service of main electrical substation. Electrical standard requirements have been taken into account to verified the results performed.Overloads of electrical machines, voltage values on the pantograph, step and touch voltages and voltage unbalances have been calculated.
2019
19th IEEE International conference on environment and electrical engineering and 2019 IEEE industrial and commercial power systems europe, EEEIC/I and CPS Europe 2019
2 x 25 kV; metro system; power analysis; power quality; railway systems
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
A high traffic density metro electrfied at 2x25 kV 50 Hz / Lamedica, R.; Midili, A.; Ruvio, A.; Guidi Buffarini, G.; Carones, N.; Laurini, M.. - (2019), pp. 1-6. (Intervento presentato al convegno 19th IEEE International conference on environment and electrical engineering and 2019 IEEE industrial and commercial power systems europe, EEEIC/I and CPS Europe 2019 tenutosi a Genoa; Italy) [10.1109/EEEIC.2019.8783848].
File allegati a questo prodotto
File Dimensione Formato  
Lamedica_A high traffic _2019.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.16 MB
Formato Adobe PDF
1.16 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1355551
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact