Purpose: This study was directed to compare diagnostic accuracy of dual-phase cone beam computed tomography (DP-CBCT) vs pre-procedural second line imaging modality (SLIM [multidetector computed tomography and magnetic resonance imaging]) to detect and characterize hepatocellular carcinoma (HCC) in cirrhotic patients with indication for trans-arterial chemoembolization (TACE). Methods: This is a single centre, retrospective, and observational study. Exclusion criteria were not-assisted DP-CBCT TACE, and unavailable follow-up SLIM. We evaluated 280 consecutive patients (January/2015-Febraury/2019). Seventy-two patients were eligible. Three radiologists in consensus reviewed: pre-procedural SLIM, DP-CBCT, and SLIM at follow-up, with 4 months of interval between each reading. Hyper-vascular foci (HVF) were detected and characterized. Diameter was recorded. Radiological behaviour, according to LI‐RADS criteria, of HFV throughout follow-up time was the reference standard. Diagnostic accuracy was calculated for pre-procedural SLIM and DP-CBCT and evaluated through receiver operating characteristic curve. HVF only visible on DP-CBCT (defined as occult) were analysed. Tumour diameters were compared. Results: Median time between pre-procedural SLIM and DP-CBCT and between DP-CBCT and definitive radiological diagnosis of HVF were 46.0 days (95%CI 36.5–55.0) and 30.5 days (95%CI 29.0–33.0), respectively. DP-CBCT had a better diagnostic performance than pre-examination SLIM (sensitivity 99%vs78%; specificity 89%vs85%; PPV 99%vs99%; NPV 92%vs30%; and accuracy 94%vs79%). DP-CBCT diagnosed 63 occult HVF. Occult HCC were 54/243 (22.2%). Six were occult angiomas. Three were false positive. Mean diameter was significantly higher in DP-CBCT vs pre-procedural SLIM (+7.5% [95%CI 3.7–11.3], p < 0.05). Conclusions: DP-CBCT has a better diagnostic accuracy and NPV than pre-procedural SLIM in cirrhotic patients with indication for TACE.

Intra-procedural dual phase cone beam computed tomography has a better diagnostic accuracy over pre-procedural MRI and MDCT in detection and characterization of HCC in cirrhotic patients undergoing TACE procedure / Lucatelli, P.; De Rubeis, G.; Ginnani Corradini, L.; Basilico, F.; Di Martino, M.; Lai, Q.; Ginanni Corradini, S.; Cannavale, A.; Nardis, P. G.; Corona, M.; Saba, L.; Catalano, C.; Bezzi, M.. - In: EUROPEAN JOURNAL OF RADIOLOGY. - ISSN 0720-048X. - 124:(2020). [10.1016/j.ejrad.2019.108806]

Intra-procedural dual phase cone beam computed tomography has a better diagnostic accuracy over pre-procedural MRI and MDCT in detection and characterization of HCC in cirrhotic patients undergoing TACE procedure

Lucatelli P.
Primo
;
De Rubeis G.
Secondo
;
Basilico F.;Di Martino M.;Lai Q.;Ginanni Corradini S.;Cannavale A.;Nardis P. G.;Corona M.;Catalano C.
Penultimo
;
Bezzi M.
Ultimo
2020

Abstract

Purpose: This study was directed to compare diagnostic accuracy of dual-phase cone beam computed tomography (DP-CBCT) vs pre-procedural second line imaging modality (SLIM [multidetector computed tomography and magnetic resonance imaging]) to detect and characterize hepatocellular carcinoma (HCC) in cirrhotic patients with indication for trans-arterial chemoembolization (TACE). Methods: This is a single centre, retrospective, and observational study. Exclusion criteria were not-assisted DP-CBCT TACE, and unavailable follow-up SLIM. We evaluated 280 consecutive patients (January/2015-Febraury/2019). Seventy-two patients were eligible. Three radiologists in consensus reviewed: pre-procedural SLIM, DP-CBCT, and SLIM at follow-up, with 4 months of interval between each reading. Hyper-vascular foci (HVF) were detected and characterized. Diameter was recorded. Radiological behaviour, according to LI‐RADS criteria, of HFV throughout follow-up time was the reference standard. Diagnostic accuracy was calculated for pre-procedural SLIM and DP-CBCT and evaluated through receiver operating characteristic curve. HVF only visible on DP-CBCT (defined as occult) were analysed. Tumour diameters were compared. Results: Median time between pre-procedural SLIM and DP-CBCT and between DP-CBCT and definitive radiological diagnosis of HVF were 46.0 days (95%CI 36.5–55.0) and 30.5 days (95%CI 29.0–33.0), respectively. DP-CBCT had a better diagnostic performance than pre-examination SLIM (sensitivity 99%vs78%; specificity 89%vs85%; PPV 99%vs99%; NPV 92%vs30%; and accuracy 94%vs79%). DP-CBCT diagnosed 63 occult HVF. Occult HCC were 54/243 (22.2%). Six were occult angiomas. Three were false positive. Mean diameter was significantly higher in DP-CBCT vs pre-procedural SLIM (+7.5% [95%CI 3.7–11.3], p < 0.05). Conclusions: DP-CBCT has a better diagnostic accuracy and NPV than pre-procedural SLIM in cirrhotic patients with indication for TACE.
2020
computerized tomography, X ray; cone-beam computed tomography; hepatocellular cancer; magnetic resonance imaging; therapeutic chemoembolization
01 Pubblicazione su rivista::01a Articolo in rivista
Intra-procedural dual phase cone beam computed tomography has a better diagnostic accuracy over pre-procedural MRI and MDCT in detection and characterization of HCC in cirrhotic patients undergoing TACE procedure / Lucatelli, P.; De Rubeis, G.; Ginnani Corradini, L.; Basilico, F.; Di Martino, M.; Lai, Q.; Ginanni Corradini, S.; Cannavale, A.; Nardis, P. G.; Corona, M.; Saba, L.; Catalano, C.; Bezzi, M.. - In: EUROPEAN JOURNAL OF RADIOLOGY. - ISSN 0720-048X. - 124:(2020). [10.1016/j.ejrad.2019.108806]
File allegati a questo prodotto
File Dimensione Formato  
Lucatelli_postprint_Intra-procedural dual_2019.pdf

accesso aperto

Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Creative commons
Dimensione 2.32 MB
Formato Adobe PDF
2.32 MB Adobe PDF
Lucatelli_Intra-procedural dual_2020.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 4.19 MB
Formato Adobe PDF
4.19 MB Adobe PDF   Contatta l'autore