This paper focuses on the seismic evaluation of the Bell Towers of Lima’s Cathedral. The church, which dates back to 1535, has been modified and reconstructed several times over the centuries, changing its structural assembly in terms of lightening and strengthening. Focusing on the massive 45 m tall towers, linear kinematic analyses have been performed in order to evaluate their vulnerability. The results show how its actual performance is far below the safety requirements of the Peruvian code. Such code, however, lacks of regulations aimed at increasing structural safety of existing buildings and, thus, it does not provide any reference on the minimum safety level to reach on a monumental construction such as the Cathedral. A simple intervention using steel ties has been proposed in order to increase such performance on nearly all the considered collapse mechanisms, however the reference value of structural safety, due to absence of other prescription, has been set as the ultimate limit state for new constructions.

Bell towers of Lima’s Cathedral: An architectural-engineering combined seismic study / Rossi, E.; Scaletti, A.; Tarque, N.; Grande, F.; Gigliotti, R.; Faggella, M.. - (2019), pp. 1498-1506. (Intervento presentato al convegno SAHC 2018, 11th International Conference on Structural Analysis of Historical Constructions tenutosi a Cusco, Perù) [10.1007/978-3-319-99441-3_161].

Bell towers of Lima’s Cathedral: An architectural-engineering combined seismic study

Gigliotti R.;
2019

Abstract

This paper focuses on the seismic evaluation of the Bell Towers of Lima’s Cathedral. The church, which dates back to 1535, has been modified and reconstructed several times over the centuries, changing its structural assembly in terms of lightening and strengthening. Focusing on the massive 45 m tall towers, linear kinematic analyses have been performed in order to evaluate their vulnerability. The results show how its actual performance is far below the safety requirements of the Peruvian code. Such code, however, lacks of regulations aimed at increasing structural safety of existing buildings and, thus, it does not provide any reference on the minimum safety level to reach on a monumental construction such as the Cathedral. A simple intervention using steel ties has been proposed in order to increase such performance on nearly all the considered collapse mechanisms, however the reference value of structural safety, due to absence of other prescription, has been set as the ultimate limit state for new constructions.
2019
SAHC 2018, 11th International Conference on Structural Analysis of Historical Constructions
Bell towers; Historical buildings; Kinematic analysis; Partial retrofit; Pushover
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Bell towers of Lima’s Cathedral: An architectural-engineering combined seismic study / Rossi, E.; Scaletti, A.; Tarque, N.; Grande, F.; Gigliotti, R.; Faggella, M.. - (2019), pp. 1498-1506. (Intervento presentato al convegno SAHC 2018, 11th International Conference on Structural Analysis of Historical Constructions tenutosi a Cusco, Perù) [10.1007/978-3-319-99441-3_161].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1349670
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact