In the framework of the LHC Injector Upgrade program, a new normal conducting linac (Linac4) operating at the frequency of 352 MHz has been recently commissioned to the final energy of 160 MeV. Linac4 will be connected to the LHC injector chain in 2020 and it is expected to provide a 40 mA, 400 µs H− beam for charge-exchange injection into the Proton Synchrotron Booster. The Linac4 pre-injector includes a 45 keV, 2 MHz RF-driven, cesiated H− source, a magnetic Low Energy Beam Transport and a 3 MeV Radio Frequency Quadrupole. Currently the pre-injector is limited to beam currents of 30 mA. A campaign of beam measurements at 45 keV under controlled variation of the system parameters has been performed during 2017 to improve the understanding of pre-injector dynamics and to devise a method to overcome the present limitation. This paper reports the results of the measurements and preliminary conclusions on the dependence of current and emittance on the relevant parameters.

Linac4 source extraction and low energy beam transport study / Noll, Daniel; Bencini, Vittorio; Lallement, Jean-Baptiste; Lettry, Jaques; Lombardi, Alessandra; Di Lorenzo, Francesco; Mattei, Stefano; O’Neil, Micheal. - 2011:1(2018). (Intervento presentato al convegno 17th International Conference on Ion Sources tenutosi a Geneva; Switzerland).

Linac4 source extraction and low energy beam transport study

Vittorio Bencini;
2018

Abstract

In the framework of the LHC Injector Upgrade program, a new normal conducting linac (Linac4) operating at the frequency of 352 MHz has been recently commissioned to the final energy of 160 MeV. Linac4 will be connected to the LHC injector chain in 2020 and it is expected to provide a 40 mA, 400 µs H− beam for charge-exchange injection into the Proton Synchrotron Booster. The Linac4 pre-injector includes a 45 keV, 2 MHz RF-driven, cesiated H− source, a magnetic Low Energy Beam Transport and a 3 MeV Radio Frequency Quadrupole. Currently the pre-injector is limited to beam currents of 30 mA. A campaign of beam measurements at 45 keV under controlled variation of the system parameters has been performed during 2017 to improve the understanding of pre-injector dynamics and to devise a method to overcome the present limitation. This paper reports the results of the measurements and preliminary conclusions on the dependence of current and emittance on the relevant parameters.
2018
17th International Conference on Ion Sources
ion sources, linac4, source extraction
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Linac4 source extraction and low energy beam transport study / Noll, Daniel; Bencini, Vittorio; Lallement, Jean-Baptiste; Lettry, Jaques; Lombardi, Alessandra; Di Lorenzo, Francesco; Mattei, Stefano; O’Neil, Micheal. - 2011:1(2018). (Intervento presentato al convegno 17th International Conference on Ion Sources tenutosi a Geneva; Switzerland).
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1347047
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact