Several studies have shown that occupational exposure to anesthetic gases might be higher during pediatric surgery, probably due to the increased use of inhalational induction techniques. Our study aims to assess the level of exposure to sevoflurane in two rooms of pediatric surgery, using multi-point sampling method for environmental monitoring. The gas concentrations as well as its dispersion were measured in strategic points in the rooms for a total of 44 surgical interventions. Although the average of these concentrations has been rather low (1.32, SD +/- 1:55 ppm), the results obtained have documented a significant distribution kinetics difference inside the rooms as function of multiple factors among which there were the anesthetic technique used and the team involved. Therefore the method described allows to correctly analyze the spread of anesthetic gases and suggests a different risk stratification which may be dependent on the professional work.

Esposizione Professionale al Sevofluorane nelle sale operatorie di pertinenza pediatrica: il contributo del monitoraggio ambientale con tecnica multi-punto nella valutazione del rischio / Zaffina, S; Camisa, V; Poscia, A; Tucci, Mg; Montaldi, V; Cerabona, V; Wachocka, M; Moscato, U.. - In: GIORNALE ITALIANO DI MEDICINA DEL LAVORO ED ERGONOMIA. - ISSN 1592-7830. - 3 Supplemento:34(2012), pp. 266-268.

Esposizione Professionale al Sevofluorane nelle sale operatorie di pertinenza pediatrica: il contributo del monitoraggio ambientale con tecnica multi-punto nella valutazione del rischio.

Cerabona V;
2012

Abstract

Several studies have shown that occupational exposure to anesthetic gases might be higher during pediatric surgery, probably due to the increased use of inhalational induction techniques. Our study aims to assess the level of exposure to sevoflurane in two rooms of pediatric surgery, using multi-point sampling method for environmental monitoring. The gas concentrations as well as its dispersion were measured in strategic points in the rooms for a total of 44 surgical interventions. Although the average of these concentrations has been rather low (1.32, SD +/- 1:55 ppm), the results obtained have documented a significant distribution kinetics difference inside the rooms as function of multiple factors among which there were the anesthetic technique used and the team involved. Therefore the method described allows to correctly analyze the spread of anesthetic gases and suggests a different risk stratification which may be dependent on the professional work.
2012
sevofluorane; monitoraggio ambientale, esposizione professionale
01 Pubblicazione su rivista::01a Articolo in rivista
Esposizione Professionale al Sevofluorane nelle sale operatorie di pertinenza pediatrica: il contributo del monitoraggio ambientale con tecnica multi-punto nella valutazione del rischio / Zaffina, S; Camisa, V; Poscia, A; Tucci, Mg; Montaldi, V; Cerabona, V; Wachocka, M; Moscato, U.. - In: GIORNALE ITALIANO DI MEDICINA DEL LAVORO ED ERGONOMIA. - ISSN 1592-7830. - 3 Supplemento:34(2012), pp. 266-268.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1344597
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 6
  • ???jsp.display-item.citation.isi??? ND
social impact