In this work, the physical and chemical properties of a novel zwitterionic LC stationary phase are applied to the development, validation and application of a new fast and reliable method devoted to the analysis of GHB (gamma-hydroxybutyric acid) and its relatively new discovered glucuronide metabolite in hair. The obtained sensitivity, expressed as limit of detection (LOD) and quantification (LOQ), were 0.033 and 0.10 ng/mg for GHB and 0.11 and 0.37 ng/mg, for GHB-glucuronide respectively. Linearity was assessed between LOQ and 50 ng/mg for both compounds. GHB and GHB-glucuronide extraction from hair matrix was maintained simple and consisted in an acidified-solvent incubation. No samples purification was required before LC–MS/MS analysis. The method was finally applied to 65 real hair sample, 60 adults and 5 children below 2 years old. The obtained results highlighted that GHB concentrations were in the range 0.11–0.96 ng/mg (average 0.38 ± 0.25 ng/mg) in 44 cases (68%) while in 21 samples GHB concentrations were in the range between LOD and LOQ (0.033–0.1 ng/mg). GHB-glucuronide was detected in few samples (n. 3) at levels below LOQ. The interest on these molecules relies on the fact that GHB is both a naturally occurring inhibitory neurotransmitter in the central nervous system and an illicit drug often experienced by victims of drug-facilitated sexual assault. GHB-glucuronide was firstly identified in urine by the group of Petersen in 2013 and, as per analogy to ethyl glucuronide, it was proposed as a longer biomarker for GHB intoxication.
Zwitterionic HILIC stationary phase as a valuable alternative in separative techniques. Application to the analysis of gamma-hydroxybutyric acid and its metabolite in hair / Pascali, J. P.; Fais, P.; Vaiano, F.; Ciolini, A.; Bertol, E.. - In: JOURNAL OF CHROMATOGRAPHY. B. - ISSN 1570-0232. - 1134-1135:(2019), pp. 1-6. [10.1016/j.jchromb.2019.121876]
Zwitterionic HILIC stationary phase as a valuable alternative in separative techniques. Application to the analysis of gamma-hydroxybutyric acid and its metabolite in hair
Vaiano F.;
2019
Abstract
In this work, the physical and chemical properties of a novel zwitterionic LC stationary phase are applied to the development, validation and application of a new fast and reliable method devoted to the analysis of GHB (gamma-hydroxybutyric acid) and its relatively new discovered glucuronide metabolite in hair. The obtained sensitivity, expressed as limit of detection (LOD) and quantification (LOQ), were 0.033 and 0.10 ng/mg for GHB and 0.11 and 0.37 ng/mg, for GHB-glucuronide respectively. Linearity was assessed between LOQ and 50 ng/mg for both compounds. GHB and GHB-glucuronide extraction from hair matrix was maintained simple and consisted in an acidified-solvent incubation. No samples purification was required before LC–MS/MS analysis. The method was finally applied to 65 real hair sample, 60 adults and 5 children below 2 years old. The obtained results highlighted that GHB concentrations were in the range 0.11–0.96 ng/mg (average 0.38 ± 0.25 ng/mg) in 44 cases (68%) while in 21 samples GHB concentrations were in the range between LOD and LOQ (0.033–0.1 ng/mg). GHB-glucuronide was detected in few samples (n. 3) at levels below LOQ. The interest on these molecules relies on the fact that GHB is both a naturally occurring inhibitory neurotransmitter in the central nervous system and an illicit drug often experienced by victims of drug-facilitated sexual assault. GHB-glucuronide was firstly identified in urine by the group of Petersen in 2013 and, as per analogy to ethyl glucuronide, it was proposed as a longer biomarker for GHB intoxication.File | Dimensione | Formato | |
---|---|---|---|
Pascali_Zwitterionic_2019.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
527.57 kB
Formato
Adobe PDF
|
527.57 kB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.