The E and B Experiment (EBEX) was a long-duration balloon-borne instrument designed to measure the polarization of the cosmic microwave background (CMB) radiation. EBEX was the first balloon-borne instrument to implement a kilopixel array of transition edge sensor (TES) bolometric detectors and the first CMB experiment to use the digital version of the frequency domain multiplexing system for readout of the TES array. The scan strategy relied on 40 s peak-to-peak constant-velocity azimuthal scans. We discuss the unique demands on the design and operation of the payload that resulted from these new technologies and the scan strategy. We describe the solutions implemented, including the development of a power system designed to provide a total of at least 2.3 kW, a cooling system to dissipate 590 W consumed by the detectors' readout system, software to manage and handle the data of the kilopixel array, and specialized attitude reconstruction software. We present flight performance data showing faultless management of the TES array, adequate powering and cooling of the readout electronics, and constraint of attitude reconstruction errors such that the spurious B-modes they induced were less than 10% of the CMB B-mode power spectrum with r = 0.05.
The EBEX Balloon-borne Experiment - Gondola, Attitude Control, and Control Software / Aboobaker, A.; Ade, P.; Araujo, D.; Aubin, F.; Baccigalupi, C.; Bao, C.; Chapman, D.; Didier, J.; Dobbs, M.; Grainger, W.; Hanany, S.; Helson, K.; Hillbrand, S.; Hubmayr, J.; Jaffe, A.; Johnson, B.; Jones, T.; Klein, J.; Korotkov, A.; Lee, A.; Levinson, L.; Limon, M.; Macdermid, K.; Miller, A. D.; Milligan, M.; Moncelsi, L.; Pascale, E.; Raach, K.; Reichborn-Kjennerud, B.; Sagiv, I.; Tucker, C.; Tucker, G. S.; Westbrook, B.; Young, K.; Zilic, K.. - In: THE ASTROPHYSICAL JOURNAL. - ISSN 0004-637X. - 239:1(2018), p. 9. [10.3847/1538-4365/aae435]
The EBEX Balloon-borne Experiment - Gondola, Attitude Control, and Control Software
Pascale E.;
2018
Abstract
The E and B Experiment (EBEX) was a long-duration balloon-borne instrument designed to measure the polarization of the cosmic microwave background (CMB) radiation. EBEX was the first balloon-borne instrument to implement a kilopixel array of transition edge sensor (TES) bolometric detectors and the first CMB experiment to use the digital version of the frequency domain multiplexing system for readout of the TES array. The scan strategy relied on 40 s peak-to-peak constant-velocity azimuthal scans. We discuss the unique demands on the design and operation of the payload that resulted from these new technologies and the scan strategy. We describe the solutions implemented, including the development of a power system designed to provide a total of at least 2.3 kW, a cooling system to dissipate 590 W consumed by the detectors' readout system, software to manage and handle the data of the kilopixel array, and specialized attitude reconstruction software. We present flight performance data showing faultless management of the TES array, adequate powering and cooling of the readout electronics, and constraint of attitude reconstruction errors such that the spurious B-modes they induced were less than 10% of the CMB B-mode power spectrum with r = 0.05.File | Dimensione | Formato | |
---|---|---|---|
Aboobaker_The EBEX_2018.pdf
accesso aperto
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
5.57 MB
Formato
Adobe PDF
|
5.57 MB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.