Purpose: This study investigates a novel gamma tomosynthesis (GT) method based on a variable tilt-angle, parallel-hole collimator (VAPHC) which, mounting to a conventional gamma, is able to perform high-resolution three-dimensional imaging. Methods: The VAPHC has the remarkable feature to be modular, consisting of independent collimation elements able to tilt according to variable angles [−45° to +45°]. Spatial resolutions were measured in reconstructed GT images using a point source at different source-to-collimator distances, while sensitivity was evaluated over the range of slant angles using a disk-source. Image contrast (IC) and contrast-to-noise-ratio (CNR) of sub-centimeters tumors were evaluated using a breast phantom containing a background activity and spheres filled with 99mTc to simulate lesions at two depths. Breast phantom GT images were compared with planar and circularorbit SPECT acquisitions of equal scan-time. Results: Planar spatial resolutions range from 9 to 14mm over a depth range of 6–10 cm; spatial resolution in depth dimension becomes two times greater than those in the other dimensions. The measured sensitivity decreases from 9 cps/μCi to 6 cps/μCi varying the slant angle from 5° to 45°. The measured IC and CNR of GT reconstructed images demonstrated that it was possible to improve the spatial resolution/sensitivity trade-off. Conclusions: The proposed GT based VAPHC demonstrated the potential for superior spatial resolution and contrast compared to planar and SPECT acquisitions. A conventional gamma camera equipped with the VAPHC could be located at the minimum distance from the patient, thus improving detection, localisation and characterisation of sub-centimetre lesions.
Variable tilt-angle, parallel-hole collimation system for high-resolution molecular imaging gamma tomosynthesis / Longo, Mariaconcetta; Pani, Roberto; Pellegrini, Rosanna; Nerina Cinti, Maria; Frantellizzi, Viviana; De Vincentis, Giuseppe. - In: PHYSICA MEDICA. - ISSN 1120-1797. - 67:(2019), pp. 155-165. [10.1016/j.ejmp.2019.10.028]
Variable tilt-angle, parallel-hole collimation system for high-resolution molecular imaging gamma tomosynthesis
Longo, Mariaconcetta
Primo
;Pani, RobertoSecondo
;Pellegrini, Rosanna;Nerina Cinti, Maria;Frantellizzi, VivianaPenultimo
;De Vincentis, GiuseppeUltimo
2019
Abstract
Purpose: This study investigates a novel gamma tomosynthesis (GT) method based on a variable tilt-angle, parallel-hole collimator (VAPHC) which, mounting to a conventional gamma, is able to perform high-resolution three-dimensional imaging. Methods: The VAPHC has the remarkable feature to be modular, consisting of independent collimation elements able to tilt according to variable angles [−45° to +45°]. Spatial resolutions were measured in reconstructed GT images using a point source at different source-to-collimator distances, while sensitivity was evaluated over the range of slant angles using a disk-source. Image contrast (IC) and contrast-to-noise-ratio (CNR) of sub-centimeters tumors were evaluated using a breast phantom containing a background activity and spheres filled with 99mTc to simulate lesions at two depths. Breast phantom GT images were compared with planar and circularorbit SPECT acquisitions of equal scan-time. Results: Planar spatial resolutions range from 9 to 14mm over a depth range of 6–10 cm; spatial resolution in depth dimension becomes two times greater than those in the other dimensions. The measured sensitivity decreases from 9 cps/μCi to 6 cps/μCi varying the slant angle from 5° to 45°. The measured IC and CNR of GT reconstructed images demonstrated that it was possible to improve the spatial resolution/sensitivity trade-off. Conclusions: The proposed GT based VAPHC demonstrated the potential for superior spatial resolution and contrast compared to planar and SPECT acquisitions. A conventional gamma camera equipped with the VAPHC could be located at the minimum distance from the patient, thus improving detection, localisation and characterisation of sub-centimetre lesions.File | Dimensione | Formato | |
---|---|---|---|
Longo_Variable-tilt-angle_2019.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
2.03 MB
Formato
Adobe PDF
|
2.03 MB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.