The CUPID-0 experiment searches for neutrinoless double beta decay using the first array of enriched Zn82Se scintillating bolometers with double (heat and light) read-out. To further enhance the CUPID-0 detector performances, the heat-light correlation has been exploited to improve the energy resolution. Different decorrelation algorithms have been studied and the best result is the average reduction of the full width at half maximum (FWHM) energy resolution to (90.5±0.6) % of its original value, corresponding to a change from FWHM=(20.7±0.5) keV to FWHM=(18.7±0.5) keV at the 2615 keV γ line.

Resolution enhancement with light/heat decorrelation in CUPID-0 bolometric detector / Beretta, M.; Cardani, L.; Casali, N.; Gironi, L.; Pagnanini, L.; Bellini, F.; Brofferio, C.; Chiesa, D.; Capelli, S.; Domizio, S. Di; Pattavina, L.; Pavan, M.; Pirro, S.; Pozzi, S.; Previtali, E.; Rusconi, C.; Tomei, C.; Vignati, M.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 14:08(2019), pp. P08017-P08017. [10.1088/1748-0221/14/08/P08017]

Resolution enhancement with light/heat decorrelation in CUPID-0 bolometric detector

Cardani, L.;Casali, N.;Bellini, F.;Vignati, M.
2019

Abstract

The CUPID-0 experiment searches for neutrinoless double beta decay using the first array of enriched Zn82Se scintillating bolometers with double (heat and light) read-out. To further enhance the CUPID-0 detector performances, the heat-light correlation has been exploited to improve the energy resolution. Different decorrelation algorithms have been studied and the best result is the average reduction of the full width at half maximum (FWHM) energy resolution to (90.5±0.6) % of its original value, corresponding to a change from FWHM=(20.7±0.5) keV to FWHM=(18.7±0.5) keV at the 2615 keV γ line.
2019
Calorimeters; Double-beta decay detectors; Particle identification methods
01 Pubblicazione su rivista::01a Articolo in rivista
Resolution enhancement with light/heat decorrelation in CUPID-0 bolometric detector / Beretta, M.; Cardani, L.; Casali, N.; Gironi, L.; Pagnanini, L.; Bellini, F.; Brofferio, C.; Chiesa, D.; Capelli, S.; Domizio, S. Di; Pattavina, L.; Pavan, M.; Pirro, S.; Pozzi, S.; Previtali, E.; Rusconi, C.; Tomei, C.; Vignati, M.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 14:08(2019), pp. P08017-P08017. [10.1088/1748-0221/14/08/P08017]
File allegati a questo prodotto
File Dimensione Formato  
Beretta_Resolution_2019.pdf

accesso aperto

Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 829.65 kB
Formato Adobe PDF
829.65 kB Adobe PDF
Beretta_Resolution-enhancement_2019.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.01 MB
Formato Adobe PDF
1.01 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1322820
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 6
social impact