The 2016-2018 ongoing revision of the lEC 60156 'Insulating liquids - Determination of the breakdown voltage at power frequency' was just approved and the revised standard will be published by the end of 2018. This document will include the recommended use of a stirring system with the main purpose to reduce the scatter in the ac breakdown voltage results. The present paper reports a comparison of breakdown voltage mean values and related scatters of two different insulating liquids (traditional mineral oils and natural ester liquids) in accordance with the tests methods of the actual and 2018 upcoming revision of IEC 60156. The results presented here confirm that the modification (stirring system) introduced in the lEC standardized test method, even a simple rearrangement, is able to reduce the scatter of the mean values of the breakdown voltage of the insulating liquids. Some considerations of an alternative test method procedure introduced by the 2018 upcoming revision of lEC 60156 are also reported. © 2018 IEEE.

Standard evolution for the determination of the power frequency breakdown voltages in insulating liquids / Calcara, L.; Pompili, M.; Sangiovanni, S.; Baur, M.; Knauel, J.. - (2018), pp. 263-266. (Intervento presentato al convegno 2018 IEEE Conference on electrical insulation and dielectric phenomena (CEIDP) tenutosi a Cancun; Mexico) [10.1109/CEIDP.2018.8544887].

Standard evolution for the determination of the power frequency breakdown voltages in insulating liquids

Calcara L.;Pompili M.;Sangiovanni S.;
2018

Abstract

The 2016-2018 ongoing revision of the lEC 60156 'Insulating liquids - Determination of the breakdown voltage at power frequency' was just approved and the revised standard will be published by the end of 2018. This document will include the recommended use of a stirring system with the main purpose to reduce the scatter in the ac breakdown voltage results. The present paper reports a comparison of breakdown voltage mean values and related scatters of two different insulating liquids (traditional mineral oils and natural ester liquids) in accordance with the tests methods of the actual and 2018 upcoming revision of IEC 60156. The results presented here confirm that the modification (stirring system) introduced in the lEC standardized test method, even a simple rearrangement, is able to reduce the scatter of the mean values of the breakdown voltage of the insulating liquids. Some considerations of an alternative test method procedure introduced by the 2018 upcoming revision of lEC 60156 are also reported. © 2018 IEEE.
2018
2018 IEEE Conference on electrical insulation and dielectric phenomena (CEIDP)
dielectric liquids; IEC standards; oils; electric breakdown; minerals; breakdown voltage
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Standard evolution for the determination of the power frequency breakdown voltages in insulating liquids / Calcara, L.; Pompili, M.; Sangiovanni, S.; Baur, M.; Knauel, J.. - (2018), pp. 263-266. (Intervento presentato al convegno 2018 IEEE Conference on electrical insulation and dielectric phenomena (CEIDP) tenutosi a Cancun; Mexico) [10.1109/CEIDP.2018.8544887].
File allegati a questo prodotto
File Dimensione Formato  
Calcara_Standard_2018.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 3.38 MB
Formato Adobe PDF
3.38 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1321534
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 5
social impact