Background: In the CT assessment of the carotid plaque, the analysis of the attenuation value is a fundamental parameter in order to classify the type of the tissue that composes the plaque. The purpose of this paper is to assess the intra-plaque attenuation variability in order to verify the potential reproducibility of HU measurements. Methods: In this retrospective study, 68 consecutive patients (males 42; average age 64 ± 11 years) that underwent CT of carotid arteries were included. Exams were performed before and after administration of contrast medium and in each slice 4 different circular or elliptical ROIs (≥1 and ≤ 2 mm2) were traced and attenuation values were recorded. Wilcoxon and Mann-Whitney test were used to test the differences between the ROI. Results: A total of 192 slices were analysed. The average value of attenuation before contrast medium was 41.591(SD 8.1) HU and 54.159 (SD 15.7) in post-contrast scan. Mann-Whitney test did not find statistically significant difference among the ROI in the pre-contrast scan whereas a statistically significant differences was found in post-contrast scan. Wilcoxon analysis showed a statistically significant difference (p value = 0.001) between pre and post-contrast attenuation. Conclusion: In conclusion, results of our study suggest that ROI sampling performed in the CT dataset acquired after administration of contrast medium show significant degree of heterogeneity and a statistically significant differences compared to the baseline measurement. This effect may be driven by a different amount of contrast acquisition in some areas of the carotid artery plaque.
Carotid artery intra-plaque attenuation variability using computed tomography / Saba, L.; Anzidei, M.; de Cecco, C. N.; Porcu, MARIA LUISA; Balestrieri, Angelo; Sanfilippo, R.; Francone, M.; Mereu, A.; Lucatelli, P.; Montisci, R.; Suri, J. S.; Wintermark, M.. - In: NEUROVASCULAR IMAGING. - ISSN 2055-5792. - 2:(2016). [10.1186/s40809-016-0023-4]
Carotid artery intra-plaque attenuation variability using computed tomography
Anzidei M.Secondo
;de Cecco C. N.;PORCU, MARIA LUISA;Francone M.;Lucatelli P.;
2016
Abstract
Background: In the CT assessment of the carotid plaque, the analysis of the attenuation value is a fundamental parameter in order to classify the type of the tissue that composes the plaque. The purpose of this paper is to assess the intra-plaque attenuation variability in order to verify the potential reproducibility of HU measurements. Methods: In this retrospective study, 68 consecutive patients (males 42; average age 64 ± 11 years) that underwent CT of carotid arteries were included. Exams were performed before and after administration of contrast medium and in each slice 4 different circular or elliptical ROIs (≥1 and ≤ 2 mm2) were traced and attenuation values were recorded. Wilcoxon and Mann-Whitney test were used to test the differences between the ROI. Results: A total of 192 slices were analysed. The average value of attenuation before contrast medium was 41.591(SD 8.1) HU and 54.159 (SD 15.7) in post-contrast scan. Mann-Whitney test did not find statistically significant difference among the ROI in the pre-contrast scan whereas a statistically significant differences was found in post-contrast scan. Wilcoxon analysis showed a statistically significant difference (p value = 0.001) between pre and post-contrast attenuation. Conclusion: In conclusion, results of our study suggest that ROI sampling performed in the CT dataset acquired after administration of contrast medium show significant degree of heterogeneity and a statistically significant differences compared to the baseline measurement. This effect may be driven by a different amount of contrast acquisition in some areas of the carotid artery plaque.File | Dimensione | Formato | |
---|---|---|---|
Saba_Carotid-artery_2016.pdf
accesso aperto
Note: https://nvijournal.biomedcentral.com/articles/10.1186/s40809-016-0023-4
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Creative commons
Dimensione
1.86 MB
Formato
Adobe PDF
|
1.86 MB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.