Background. The main purpose of a biopsy is microscopic examination and diagnosis. Keeping the margins of specimens safe and readable is always fundamental to detecting marginal infiltrations or malignant transformation. Numerous options and tools have been introduced for biopsy procedures. Lasers are one of these options that provide many enhancements to clinical and surgical biopsy procedures in comparison to scalpels. Objectives. The aim of the present study is to quantify the thermal artefacts in histological specimens obtained using a CO2 laser from different oral mucosal lesions and to evaluate if the resulting thermal effect hinders the histological examination. This aim is accomplished through quantitatively and qualitatively assessing the thermal effect in both the epithelium and connective tissue. Material and methods. A super-pulsed CO2 laser (10,600 nm) was used to obtain 10 excision biopsy samples. The parameters were a power of 4.2 W in focused mode and a frequency of 80 Hz in super-pulse mode. The histological analysis was performed with an optical microscope. Computerized imaging software was utilized to quantitatively evaluate the thermal effect in both the epithelium and connective tissue expressed in microns. Results. The thermal effect of the CO2 laser was limited to the surgical resection margins in all the specimens and did not hinder the histological analysis. Thermal artefacts were observed in 3 specimens. The range of thermal effects in the epithelial tissue was between 184 μm and 2,292 μm, while in the connective tissue it was between 133 μm and 2,958 μm. Conclusions. The resulting thermal effects of using a CO2 laser did not hamper the histological evaluation. Utilizing a laser in biopsy procedures should be tailored. Not only should laser parameters and safety margins be taken into consideration but also the working time, clinical accessibility, and the nature and water content of the tissue.

Could the super-pulsed CO2 laser be used for oral excisional biopsies? / Tenore, Gianluca; Palaia, Gaspare; Mohsen, AHMED AMIR MOHAMED; Ambrogiano, Simone; DI GIOIA, Cira Rosaria Tiziana; Dominiak, Marzena; Romeo, Umberto. - In: ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE. - ISSN 1899-5276. - 28:11(2019), pp. 1513-1517. [10.17219/acem/104525]

Could the super-pulsed CO2 laser be used for oral excisional biopsies?

Gianluca Tenore
Primo
;
Gaspare Palaia
Secondo
;
Ahmed Mohsen
;
Cira Rosaria Tiziana Di Gioia;Umberto Romeo.
Ultimo
2019

Abstract

Background. The main purpose of a biopsy is microscopic examination and diagnosis. Keeping the margins of specimens safe and readable is always fundamental to detecting marginal infiltrations or malignant transformation. Numerous options and tools have been introduced for biopsy procedures. Lasers are one of these options that provide many enhancements to clinical and surgical biopsy procedures in comparison to scalpels. Objectives. The aim of the present study is to quantify the thermal artefacts in histological specimens obtained using a CO2 laser from different oral mucosal lesions and to evaluate if the resulting thermal effect hinders the histological examination. This aim is accomplished through quantitatively and qualitatively assessing the thermal effect in both the epithelium and connective tissue. Material and methods. A super-pulsed CO2 laser (10,600 nm) was used to obtain 10 excision biopsy samples. The parameters were a power of 4.2 W in focused mode and a frequency of 80 Hz in super-pulse mode. The histological analysis was performed with an optical microscope. Computerized imaging software was utilized to quantitatively evaluate the thermal effect in both the epithelium and connective tissue expressed in microns. Results. The thermal effect of the CO2 laser was limited to the surgical resection margins in all the specimens and did not hinder the histological analysis. Thermal artefacts were observed in 3 specimens. The range of thermal effects in the epithelial tissue was between 184 μm and 2,292 μm, while in the connective tissue it was between 133 μm and 2,958 μm. Conclusions. The resulting thermal effects of using a CO2 laser did not hamper the histological evaluation. Utilizing a laser in biopsy procedures should be tailored. Not only should laser parameters and safety margins be taken into consideration but also the working time, clinical accessibility, and the nature and water content of the tissue.
2019
biopsy; artefacts; carbon dioxide laser (CO2)
01 Pubblicazione su rivista::01a Articolo in rivista
Could the super-pulsed CO2 laser be used for oral excisional biopsies? / Tenore, Gianluca; Palaia, Gaspare; Mohsen, AHMED AMIR MOHAMED; Ambrogiano, Simone; DI GIOIA, Cira Rosaria Tiziana; Dominiak, Marzena; Romeo, Umberto. - In: ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE. - ISSN 1899-5276. - 28:11(2019), pp. 1513-1517. [10.17219/acem/104525]
File allegati a questo prodotto
File Dimensione Formato  
Tenore_Could-the-super-pulsed_online2019.pdf

accesso aperto

Note: http://www.advances.umed.wroc.pl/en/article/2019/28/11/1513/
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 2.2 MB
Formato Adobe PDF
2.2 MB Adobe PDF
Tenore_Could-the-super-pulsed_2019.pdf

accesso aperto

Note: http://www.advances.umed.wroc.pl/en/article/2019/28/11/1513/
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 2.19 MB
Formato Adobe PDF
2.19 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1311513
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 5
social impact