Particle therapy is a therapy technique that exploits protons or light ions to irradiate tumor targets with high accuracy. Protons and 12C ions are already used for irradiation in clinical routine, while new ions like 4He and 16O are currently being considered. Despite the indisputable physical and biological advantages of such ion beams, the planning of charged particle therapy treatments is challenged by range uncertainties, i.e. the uncertainty on the position of the maximal dose release (Bragg Peak – BP), during the treatment. To ensure correct ‘in-treatment’ dose deposition, range monitoring techniques, currently missing in light ion treatment techniques, are eagerly needed. The results presented in this manuscript indicate that charged secondary particles, mainly protons, produced by an 16O beam during target irradiation can be considered as candidates for 16O beam range monitoring. Hereafter, we report on the first yield measurements of protons, deuterons and tritons produced in the interaction of an 16O beam impinging on a PMMA target, as a function of detected energy and particle production position. Charged particles were detected at 90° and 60° with respect to incoming beam direction, and homogeneous and heterogeneous PMMA targets were used to probe the sensitivity of the technique to target inhomogeneities. The reported secondary particle yields provide essential information needed to assess the accuracy and resolution achievable in clinical conditions by range monitoring techniques based on secondary charged radiation.

Secondary radiation measurements for particle therapy applications: Charged secondaries produced by 16O ion beams in a PMMA target at large angles / Rucinski, A.; Traini, G.; Roldan, A. B.; Battistoni, G.; De Simoni, M.; Dong, Y.; Fischetti, M.; Frallicciardi, P. M.; Gioscio, E.; Mancini-Terracciano, C.; Marafini, M.; Mattei, I.; Mirabelli, R.; Muraro, S.; Sarti, A.; Schiavi, A.; Sciubba, A.; Solfaroli Camillocci, E.; Valle, S. M.; Patera, V.. - In: PHYSICA MEDICA. - ISSN 1120-1797. - 64:(2019), pp. 45-53. [10.1016/j.ejmp.2019.06.001]

Secondary radiation measurements for particle therapy applications: Charged secondaries produced by 16O ion beams in a PMMA target at large angles

Traini G.;De Simoni M.;Fischetti M.;Gioscio E.;Mancini-Terracciano C.;Mirabelli R.;Sarti A.;Schiavi A.;Sciubba A.;Solfaroli Camillocci E.;Patera V.
2019

Abstract

Particle therapy is a therapy technique that exploits protons or light ions to irradiate tumor targets with high accuracy. Protons and 12C ions are already used for irradiation in clinical routine, while new ions like 4He and 16O are currently being considered. Despite the indisputable physical and biological advantages of such ion beams, the planning of charged particle therapy treatments is challenged by range uncertainties, i.e. the uncertainty on the position of the maximal dose release (Bragg Peak – BP), during the treatment. To ensure correct ‘in-treatment’ dose deposition, range monitoring techniques, currently missing in light ion treatment techniques, are eagerly needed. The results presented in this manuscript indicate that charged secondary particles, mainly protons, produced by an 16O beam during target irradiation can be considered as candidates for 16O beam range monitoring. Hereafter, we report on the first yield measurements of protons, deuterons and tritons produced in the interaction of an 16O beam impinging on a PMMA target, as a function of detected energy and particle production position. Charged particles were detected at 90° and 60° with respect to incoming beam direction, and homogeneous and heterogeneous PMMA targets were used to probe the sensitivity of the technique to target inhomogeneities. The reported secondary particle yields provide essential information needed to assess the accuracy and resolution achievable in clinical conditions by range monitoring techniques based on secondary charged radiation.
2019
Oxygen beams; Particle therapy; Range monitoring; Secondary radiation
01 Pubblicazione su rivista::01a Articolo in rivista
Secondary radiation measurements for particle therapy applications: Charged secondaries produced by 16O ion beams in a PMMA target at large angles / Rucinski, A.; Traini, G.; Roldan, A. B.; Battistoni, G.; De Simoni, M.; Dong, Y.; Fischetti, M.; Frallicciardi, P. M.; Gioscio, E.; Mancini-Terracciano, C.; Marafini, M.; Mattei, I.; Mirabelli, R.; Muraro, S.; Sarti, A.; Schiavi, A.; Sciubba, A.; Solfaroli Camillocci, E.; Valle, S. M.; Patera, V.. - In: PHYSICA MEDICA. - ISSN 1120-1797. - 64:(2019), pp. 45-53. [10.1016/j.ejmp.2019.06.001]
File allegati a questo prodotto
File Dimensione Formato  
1-s2.0-S1120179719301383-main.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 743.99 kB
Formato Adobe PDF
743.99 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1310055
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 4
social impact