Advanced linear accelerator design may use Optical Transition Radiation (OTR) screens to measure beam spot size; for instance, such screens are foreseen in plasma based accelerators (EuPRAXIA@SPARC_LAB) or Compton machines (Gamma Beam Source@ELI-NP). Optical Transition Radiation angular distribution strongly depends on beam energy. Since OTR screens are typically placed in several positions along the Linac to monitor the beam envelope, one may perform a distributed energy measurement along the machine. Furthermore, a single shot energy measurement can be useful in plasma accelerators to measure shot to shot energy variations after the plasma interaction. Preliminary measurements of OTR angular distribution of about 100 MeV electrons have been performed at the SPARC_LAB facility. In this paper, we discuss the sensitivity of this measurement to beam divergence and others parameters, as well as the resolution required and the needed upgrades of conventional OTR diagnostics, using as an example the data collected at SPARC_LAB.
Energy measurements by means of transition radiation in novel Linacs / Marongiu, M.; Castellano, M.; Chiadroni, E.; Cianchi, A.; Franzini, G.; Giribono, A.; Mostacci, A.; Palumbo, Luigi; Shpakov, V.; Stella, A.; Variola, A.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 909:(2018), pp. 355-358. [10.1016/j.nima.2018.02.093]
Energy measurements by means of transition radiation in novel Linacs
Marongiu M.
Writing – Original Draft Preparation
;Chiadroni E.;Franzini G.;Giribono A.;Mostacci A.Investigation
;Palumbo LuigiInvestigation
;
2018
Abstract
Advanced linear accelerator design may use Optical Transition Radiation (OTR) screens to measure beam spot size; for instance, such screens are foreseen in plasma based accelerators (EuPRAXIA@SPARC_LAB) or Compton machines (Gamma Beam Source@ELI-NP). Optical Transition Radiation angular distribution strongly depends on beam energy. Since OTR screens are typically placed in several positions along the Linac to monitor the beam envelope, one may perform a distributed energy measurement along the machine. Furthermore, a single shot energy measurement can be useful in plasma accelerators to measure shot to shot energy variations after the plasma interaction. Preliminary measurements of OTR angular distribution of about 100 MeV electrons have been performed at the SPARC_LAB facility. In this paper, we discuss the sensitivity of this measurement to beam divergence and others parameters, as well as the resolution required and the needed upgrades of conventional OTR diagnostics, using as an example the data collected at SPARC_LAB.File | Dimensione | Formato | |
---|---|---|---|
Novel_Linacs_diagnostics.pdf
accesso aperto
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
488.92 kB
Formato
Adobe PDF
|
488.92 kB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.