The Cryogenic Underground Observatory for Rare Events (CUORE) is the first bolometric experiment searching for neutrinoless double beta decay that has been able to reach the 1-ton scale. The detector consists of an array of 988 TeO 2 crystals arranged in a cylindrical compact structure of 19 towers, each of them made of 52 crystals. The construction of the experiment was completed in August 2016 and the data taking started in spring 2017 after a period of commissioning and tests. In this work we present the neutrinoless double beta decay results of CUORE from examining a total TeO 2 exposure of 86.3 kg yr, characterized by an effective energy resolution of 7.7 keV FWHM and a background in the region of interest of 0.014 counts/(keV kg yr). In this physics run, CUORE placed a lower limit on the decay half-life of neutrinoless double beta decay of 130 Te ≤ 1.3 · 10 25 yr (90% C.L.). Moreover, an analysis of the background of the experiment is presented as well as the measurement of the 130 Te 2vββ decay with a resulting half-life of T 2v1/2 = [7.9 ± 0.1 (stat.) ± 0.2 (syst.)] x 10 20 yr which is the most precise measurement of the half-life and compatible with previous results.
Results from the cuore experiment / Caminata, A.; Adams, D.; Alduino, C.; Alfonso, K.; Avignone, F.; Azzolini, O.; Bari, G.; Bellini, F.; Benato, G.; Bersani, A.; Biassoni, M.; Branca, A.; Brofferio, C.; Bucci, C.; Campani, A.; Canonica, L.; Cao, X. -G.; Capelli, S.; Cappelli, L.; Cardani, L.; Carniti, P.; Casali, N.; Chiesa, D.; Chott, N.; Clemenza, M.; Copello, S.; Cosmelli, C.; Cremonesi, O.; Creswick, R.; Cushman, J.; D'Addabbo, A.; D'Aguanno, D.; Dafinei, I.; Davis, C.; Dell'Oro, S.; Deninno, M.; Di Domizio, S.; Dompe, V.; Drobizhev, A.; Fang, D. -Q.; Fantini, G.; Faverzani, M.; Ferri, E.; Ferroni, F.; Fiorini, E.; Franceschi, M. A.; Freedman, S.; Fujikawa, B.; Giachero, A.; Gironi, L.; Giuliani, A.; Gorla, P.; Gotti, C.; Gutierrez, T.; Han, K.; Heeger, K.; Hennings-Yeomans, R.; Huang, R.; Huang, H. Z.; Johnston, J.; Keppel, G.; Kolomensky, Y.; Leder, A.; Ligi, C.; Ma, Y. -G.; Marini, L.; Martinez, M.; Maruyama, R.; Mei, Y.; Moggi, N.; Morganti, S.; Napolitano, T.; Nastasi, M.; Nones, C.; Norman, E.; Novati, V.; Nucciotti, A.; Nutini, I.; O'Donnell, T.; Ouellet, J.; Pagliarone, C.; Pallavicini, M.; Pattavina, L.; Pavan, M.; Pessina, G.; Pettinacci, V.; Pira, C.; Pirro, S.; Pozzi, S.; Previtali, E.; Puiu, A.; Rosenfeld, C.; Rusconi, C.; Sakai, M.; Sangiorgio, S.; Schmidt, B.; Scielzo, N.; Singh, V.; Sisti, M.; Speller, D.; Taffarello, L.; Terranova, F.; Tomei, C.; Vignati, M.; Wagaarachchi, S.; Wang, B.; Welliver, B.; Wilson, J.; Wilson, K.; Winslow, L.; Wise, T.; Zanotti, L.; Zimmermann, S.; Zucchelli, S.. - In: UNIVERSE. - ISSN 2218-1997. - 5:1(2019), p. 10. [10.3390/universe5010010]
Results from the cuore experiment
Bellini F.;Cardani L.;Casali N.;Cosmelli C.;Dafinei I.;Dompe V.;Fantini G.;Ferroni F.;Pettinacci V.;Vignati M.;
2019
Abstract
The Cryogenic Underground Observatory for Rare Events (CUORE) is the first bolometric experiment searching for neutrinoless double beta decay that has been able to reach the 1-ton scale. The detector consists of an array of 988 TeO 2 crystals arranged in a cylindrical compact structure of 19 towers, each of them made of 52 crystals. The construction of the experiment was completed in August 2016 and the data taking started in spring 2017 after a period of commissioning and tests. In this work we present the neutrinoless double beta decay results of CUORE from examining a total TeO 2 exposure of 86.3 kg yr, characterized by an effective energy resolution of 7.7 keV FWHM and a background in the region of interest of 0.014 counts/(keV kg yr). In this physics run, CUORE placed a lower limit on the decay half-life of neutrinoless double beta decay of 130 Te ≤ 1.3 · 10 25 yr (90% C.L.). Moreover, an analysis of the background of the experiment is presented as well as the measurement of the 130 Te 2vββ decay with a resulting half-life of T 2v1/2 = [7.9 ± 0.1 (stat.) ± 0.2 (syst.)] x 10 20 yr which is the most precise measurement of the half-life and compatible with previous results.File | Dimensione | Formato | |
---|---|---|---|
Caminata_Results_2019.pdf
accesso aperto
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Creative commons
Dimensione
692.71 kB
Formato
Adobe PDF
|
692.71 kB | Adobe PDF | |
Campani_Results_2019.pdf
Open Access dal 02/02/2020
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Creative commons
Dimensione
274 kB
Formato
Adobe PDF
|
274 kB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.