RATIONALE: Despite being a hallmark and an independent prognostic factor in several cardiopulmonary diseases, ventilatory efficiency - i.e. minute ventilation/carbon dioxide output relationship (V'E/V'CO2) has never been systematically explored in cystic fibrosis (CF). OBJECTIVE: To provide a comprehensive frame of reference regarding measures of ventilatory efficiency in CF adults with normal to moderately impaired lung function and to confirm the hypothesis that V'E/V'CO2 is a sensitive marker of early lung disease. METHODS: CF patients were divided into 3 groups according to their spirometry: normal (G1), mild impairment (G2) and moderate impairment (G3) in lung function. All participants underwent incremental cardiopulmonary exercise testing on a cycle-ergometer. Lowest V'E/V'CO2 ratio (nadir) and the slope and the intercept of the linear region of the V'E/V'CO2 relationship were contrasted in a two-center retrospective analysis involving 72 CF patients and 36 healthy controls (HC). RESULTS: Compared to HC, CF patients had significantly higher V'E/V'CO2 nadir, slope and intercept (p<0.001, p<0.001 and p=0.049, respectively). Subgroup analysis revealed significant differences in nadir (p=0.001) and slope (p=0.012) values even between HC and G1. Dynamic hyperinflation related negatively with slope (p=0.045) and positively with intercept (p=0.001), whilst no impact on nadir was observed. CONCLUSIONS: Ventilatory inefficiency is a clear feature of adults with CF, even among patients with normal spirometry. V'E/V'CO2 nadir seems to be the most reliable metric to describe ventilatory efficiency in CF adults. Further prospective studies are needed to clarify whether V'E/V'CO2 could represent an useful marker in the evaluation of early lung disease in CF.

Reduced exercise ventilatory efficiency in adults with cystic fibrosis and normal to moderately impaired lung function / Di Paolo, Marcello; Teopompi, Elisabetta; Savi, Daniela; Crisafulli, Ernesto; Longo, Chiara; Tzani, Panagiota; Longo, Francesco; Ielpo, Antonella; Pisi, Giovanna; Cimino, Giuseppe; Simmonds, Nicholas J; Neder, J Alberto; Chetta, Alfredo; Palange, Paolo. - In: JOURNAL OF APPLIED PHYSIOLOGY. - ISSN 8750-7587. - 127:2(2019), pp. 501-512. [10.1152/japplphysiol.00030.2019]

Reduced exercise ventilatory efficiency in adults with cystic fibrosis and normal to moderately impaired lung function

Di Paolo, Marcello
Primo
;
Savi, Daniela;Palange, Paolo
Ultimo
2019

Abstract

RATIONALE: Despite being a hallmark and an independent prognostic factor in several cardiopulmonary diseases, ventilatory efficiency - i.e. minute ventilation/carbon dioxide output relationship (V'E/V'CO2) has never been systematically explored in cystic fibrosis (CF). OBJECTIVE: To provide a comprehensive frame of reference regarding measures of ventilatory efficiency in CF adults with normal to moderately impaired lung function and to confirm the hypothesis that V'E/V'CO2 is a sensitive marker of early lung disease. METHODS: CF patients were divided into 3 groups according to their spirometry: normal (G1), mild impairment (G2) and moderate impairment (G3) in lung function. All participants underwent incremental cardiopulmonary exercise testing on a cycle-ergometer. Lowest V'E/V'CO2 ratio (nadir) and the slope and the intercept of the linear region of the V'E/V'CO2 relationship were contrasted in a two-center retrospective analysis involving 72 CF patients and 36 healthy controls (HC). RESULTS: Compared to HC, CF patients had significantly higher V'E/V'CO2 nadir, slope and intercept (p<0.001, p<0.001 and p=0.049, respectively). Subgroup analysis revealed significant differences in nadir (p=0.001) and slope (p=0.012) values even between HC and G1. Dynamic hyperinflation related negatively with slope (p=0.045) and positively with intercept (p=0.001), whilst no impact on nadir was observed. CONCLUSIONS: Ventilatory inefficiency is a clear feature of adults with CF, even among patients with normal spirometry. V'E/V'CO2 nadir seems to be the most reliable metric to describe ventilatory efficiency in CF adults. Further prospective studies are needed to clarify whether V'E/V'CO2 could represent an useful marker in the evaluation of early lung disease in CF.
2019
cystic fibrosis; exercise testing; pulmonary gas exchange; pulmonary ventilation; ventilatory efficiency
01 Pubblicazione su rivista::01a Articolo in rivista
Reduced exercise ventilatory efficiency in adults with cystic fibrosis and normal to moderately impaired lung function / Di Paolo, Marcello; Teopompi, Elisabetta; Savi, Daniela; Crisafulli, Ernesto; Longo, Chiara; Tzani, Panagiota; Longo, Francesco; Ielpo, Antonella; Pisi, Giovanna; Cimino, Giuseppe; Simmonds, Nicholas J; Neder, J Alberto; Chetta, Alfredo; Palange, Paolo. - In: JOURNAL OF APPLIED PHYSIOLOGY. - ISSN 8750-7587. - 127:2(2019), pp. 501-512. [10.1152/japplphysiol.00030.2019]
File allegati a questo prodotto
File Dimensione Formato  
Di Paolo_Reduced_ 2019.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.63 MB
Formato Adobe PDF
1.63 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1291850
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 7
social impact