In the present paper an integrated approach of a wide range of non-destructive tests (NDTs) was applied to study an archeological ruined building located in Rome, the so-called Temple of Minerva Medica. Applied NDTs focused on the monument properties and environmental conditions affecting its structural behavior (geometry, thermal and mechanical properties, microclimatic monitoring, ambient vibration response). Two surveys were performed in August and December 2016 combining 3D laser scanning, thermal infrared, air temperature and relative humidity acquisitions. In addition, high resolution digital images were acquired and processed by stereo-photogrammetry Structure from Motion (SfM) methodology, carried out for detailed reconstruction of the crack pattern of the monument. In order to obtain information on the integrity and consistency of the masonry, a sonic testing of each pillar was also performed. The integration of the above NDTs provided quite complete and comprehensive understanding of the structural behavior and state of the building, reducing the amount of invasive measurements further needed.

Integrated approach to structural diagnosis by nondestructive techniques: The case of the Temple of Minerva Medica / Roselli, I.; Tati, A.; Fioriti, V.; Bellagamba, I.; Mongelli, M.; Romano, R.; De Canio, G.; Barbera, M.; Cianetti, M. M.. - In: ACTA IMEKO. - ISSN 0237-028X. - 7:3(2018), pp. 13-19. [10.21014/acta_imeko.v7i3.558]

Integrated approach to structural diagnosis by nondestructive techniques: The case of the Temple of Minerva Medica

Roselli I.;Bellagamba I.;Barbera M.;
2018

Abstract

In the present paper an integrated approach of a wide range of non-destructive tests (NDTs) was applied to study an archeological ruined building located in Rome, the so-called Temple of Minerva Medica. Applied NDTs focused on the monument properties and environmental conditions affecting its structural behavior (geometry, thermal and mechanical properties, microclimatic monitoring, ambient vibration response). Two surveys were performed in August and December 2016 combining 3D laser scanning, thermal infrared, air temperature and relative humidity acquisitions. In addition, high resolution digital images were acquired and processed by stereo-photogrammetry Structure from Motion (SfM) methodology, carried out for detailed reconstruction of the crack pattern of the monument. In order to obtain information on the integrity and consistency of the masonry, a sonic testing of each pillar was also performed. The integration of the above NDTs provided quite complete and comprehensive understanding of the structural behavior and state of the building, reducing the amount of invasive measurements further needed.
2018
archaeological building; integrated approach; non-destructive tests
01 Pubblicazione su rivista::01a Articolo in rivista
Integrated approach to structural diagnosis by nondestructive techniques: The case of the Temple of Minerva Medica / Roselli, I.; Tati, A.; Fioriti, V.; Bellagamba, I.; Mongelli, M.; Romano, R.; De Canio, G.; Barbera, M.; Cianetti, M. M.. - In: ACTA IMEKO. - ISSN 0237-028X. - 7:3(2018), pp. 13-19. [10.21014/acta_imeko.v7i3.558]
File allegati a questo prodotto
File Dimensione Formato  
Roselli_Integrated_2018.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 892.26 kB
Formato Adobe PDF
892.26 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1289014
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? ND
social impact