The Cold Pressor Test (CPT) is a novel diagnostic strategy to noninvasively assess the myocardial microvascular endothelial-dependent function using perfusion magnetic resonance imaging (MRI). Spleen perfusion is modulated by a complex combination of several mechanisms involving the autonomic nervous system and vasoactive mediators release. In this context, the effects of cold temperature on splenic blood flow (SBF) still need to be clarified. Ten healthy subjects were studied by MRI. MRI protocol included the acquisition of GRE T1-weighted sequence ("first pass perfusion") during gadolinium administration (0.1mmol/kg of Gd-DOTA at flow of 3.0 ml/s), at rest and after CPT. Myocardial blood flow (MBF) and SBF were measured by applying Fermi function deconvolution, using the blood pool input function sampled from the left ventricle cavity. MBF and SBF values after performing CPT were significantly higher than rest values (SBF at rest: 0.65 ± 0.15 ml/min/g Vs. SBF after CPT: 0.90 ± 0.14 ml/min/g, p: <0.001; MBF at rest: 0.90 ± 0.068 ml/min/g Vs. MBF after CPT: 1.22 ± 0.098 ml/min/g, p<0.005). Both SBF and MBF increased in all patients during the CPT. In particular, the CPT-induced increase was 43% ± 29% for SBF and 36.5% ± 17% for MBF. CPT increases SBF in normal subjects. The characterization of a standard perfusion response to cold might allow the use of the spleen as reference marker for the adequacy of cold stimulation during myocardial perfusion MRI.

Splenic blood flow increases after hypothermic stimulus (Cold Pressor Test): a perfusion magnetic resonance study / Galea, Nicola; Cundari, Giulia; Borrazzo, Cristian; Pambianchi, Giacomo; Bracci, Angelica; Rosato, Edoardo; Francone, Marco; Carbone, Iacopo; Catalano, Carlo. - In: BIOMED RESEARCH INTERNATIONAL. - ISSN 2314-6133. - 2019:(2019), pp. 1-7. [10.1155/2019/8437927]

Splenic blood flow increases after hypothermic stimulus (Cold Pressor Test): a perfusion magnetic resonance study

Galea, Nicola
Primo
;
CUNDARI, GIULIA
Secondo
;
Borrazzo, Cristian;PAMBIANCHI, GIACOMO;Rosato, Edoardo;Francone, Marco;Carbone, Iacopo
Penultimo
;
Catalano, Carlo
Ultimo
2019

Abstract

The Cold Pressor Test (CPT) is a novel diagnostic strategy to noninvasively assess the myocardial microvascular endothelial-dependent function using perfusion magnetic resonance imaging (MRI). Spleen perfusion is modulated by a complex combination of several mechanisms involving the autonomic nervous system and vasoactive mediators release. In this context, the effects of cold temperature on splenic blood flow (SBF) still need to be clarified. Ten healthy subjects were studied by MRI. MRI protocol included the acquisition of GRE T1-weighted sequence ("first pass perfusion") during gadolinium administration (0.1mmol/kg of Gd-DOTA at flow of 3.0 ml/s), at rest and after CPT. Myocardial blood flow (MBF) and SBF were measured by applying Fermi function deconvolution, using the blood pool input function sampled from the left ventricle cavity. MBF and SBF values after performing CPT were significantly higher than rest values (SBF at rest: 0.65 ± 0.15 ml/min/g Vs. SBF after CPT: 0.90 ± 0.14 ml/min/g, p: <0.001; MBF at rest: 0.90 ± 0.068 ml/min/g Vs. MBF after CPT: 1.22 ± 0.098 ml/min/g, p<0.005). Both SBF and MBF increased in all patients during the CPT. In particular, the CPT-induced increase was 43% ± 29% for SBF and 36.5% ± 17% for MBF. CPT increases SBF in normal subjects. The characterization of a standard perfusion response to cold might allow the use of the spleen as reference marker for the adequacy of cold stimulation during myocardial perfusion MRI.
2019
splenic blood flow; perfusion; magnetic resonance; cold pressor test
01 Pubblicazione su rivista::01a Articolo in rivista
Splenic blood flow increases after hypothermic stimulus (Cold Pressor Test): a perfusion magnetic resonance study / Galea, Nicola; Cundari, Giulia; Borrazzo, Cristian; Pambianchi, Giacomo; Bracci, Angelica; Rosato, Edoardo; Francone, Marco; Carbone, Iacopo; Catalano, Carlo. - In: BIOMED RESEARCH INTERNATIONAL. - ISSN 2314-6133. - 2019:(2019), pp. 1-7. [10.1155/2019/8437927]
File allegati a questo prodotto
File Dimensione Formato  
Galea_splenic-blood_2019.pdf

accesso aperto

Note: https://www.hindawi.com/journals/bmri/2019/8437927/
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 2.31 MB
Formato Adobe PDF
2.31 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1282903
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact