Objectives: The primary objective was to quantify the risk of perinatal mortality in non-anomalous monochorionic monoamniotic (MCMA) twin pregnancies complicated by birth-weight (BW) discordance. The secondary objectives were to investigate the effect of inpatient vs outpatient fetal monitoring on the risk of mortality in weight-discordant MCMA twin pregnancies, and to explore the predictive accuracy of BW discordance for perinatal mortality. Methods: This analysis included data on 242 MCMA twin pregnancies (484 fetuses) from three major research collaboratives on twin pregnancy (MONOMONO, STORK and NorSTAMP). The primary outcomes were the risks of intrauterine (IUD), neonatal (NND) and perinatal (PND) death, according to weight discordance at birth from ≥ 10% to ≥ 30%. The secondary outcomes were the association of inpatient vs outpatient fetal monitoring with the risk of mortality in weight-discordant pregnancies, and the accuracy of BW discordance in predicting mortality. Logistic regression and receiver-operating-characteristics-curve analyses were used to analyze the data. Results: The risk of IUD was significantly increased in MCMA twin pregnancies with BW discordance ≥ 10% (odds ratio (OR), 2.2; 95% CI, 1.1-4.4; P = 0.022) and increased up to an OR of 4.4 (95% CI, 1.3-14.4; P = 0.001) in those with BW discordance ≥ 30%. This association remained significant on multivariate logistic regression analysis for BW-discordance cut-offs ≥ 20%. However, weight discordance had low predictive accuracy for mortality, with areas under the receiver-operating-characteristics curve of 0.60 (95% CI, 0.46-0.73), 0.52 (95% CI, 0.33-0.72) and 0.57 (95% CI, 0.45-0.68) for IUD, NND and PND, respectively. There was no difference in the risk of overall IUD, single IUD, double IUD, NND or PND between pregnancies managed as an inpatient compared with those managed as an outpatient, for any BW-discordance cut-off. Conclusions: MCMA twin pregnancies with BW discordance are at increased risk of fetal death, signaling a need for increased levels of monitoring. Despite this, the predictive accuracy for mortality is low; thus, detection of BW discordance alone should not trigger intervention, such as iatrogenic delivery. The current data do not demonstrate an advantage of inpatient over outpatient management in these cases.

Weight discordance and perinatal mortality in monoamniotic twin pregnancies: analysis of the MONOMONO, NorSTAMP and STORK multiple pregnancy cohorts / Saccone, Gabriele; Khalil, Asma; Thilanagathan, Basky; Glinianaia, Svetlana; Berghella, Vincenzo; D'Antonio, Francesco; Locci, Mariavittoria; Ghi, Tullio; Frusca, Tiziana; Lanna, Mariano; Faiola, Stefano; Fichera, Anna; Prefumo, Federico; Rizzo, Giuseppe; Bosi, Costanza; Arduino, Bruno; D'Alessandro, Pietro; Borgo, Maria; Arduino, Silvana; Cantanna, Elisabetta; Simonazzi, Giuliana; Rizzo, Nicola; Francesca, Giorgetta; Seravalli, Viola; Miller, Jena L.; Rita Magro‐Malosso, Elena; Di Tommaso, Mariarosaria; Dall'Asta, Andrea; Galli, Letizia; Volpe, Nicola; Visentin, Silvia; Cosmi, Erich; Sarno, Laura; Caissutti, Claudia; Driul, Lorenza; Anastasio, Hannah; DI MASCIO, Daniele; BENEDETTI PANICI, Pierluigi; Vena, Flaminia; Brunelli, Roberto; Ciardulli, Andrea; Schoen, Corina; Suhag, Anju; Maria Gambacorti‐Passerini, Zita; Angeles Anaya Baz, Maria; Magoga, Giulia; Busato, Enrico; Filippi, Elisa; José Rodriguez Suárez, María; Gamez Alderete, Francisco; Alonso Ortuno, Paula; Vitagliano, Amerigo; Mollo, Antonio; Raffone, Antonio; Vendola, Marianne; Navaneethan, Preethi; Wimalasundera, Ruwan; Napolitano, Raffaele; Imma Aquino, Carmen; D'Agostino, Serena; Gallo, Cinzia; Maria Maruotti, Giuseppe; Elena Flacco, Maria; Baschat, Ahmet A.; Venturella, Roberta; Guida, Maurizio; Martinelli, Pasquale; Zullo Therese Hannon, Fulvio; Sturgiss, Stephen N.; Rankin, Judith; Miller, Nicola; Martin, Danielle; Bahamie, Arash; Bhide, Amar; Papageorghiou, Aris; Deans, Anne; Morgan, Kim; Egbor, Michael; Matiluko, Adetunji; Ellis, Cheryl; Gandhi, Hina; Hamid, Rosol; Hutt, Renata; Roberts, Lesley; Pakarian, Faz; Peregrine, Elisabeth. - In: ULTRASOUND IN OBSTETRICS & GYNECOLOGY. - ISSN 0960-7692. - 55:3(2020), pp. 332-338. [10.1002/uog.20357]

Weight discordance and perinatal mortality in monoamniotic twin pregnancies: analysis of the MONOMONO, NorSTAMP and STORK multiple pregnancy cohorts

Daniele Di Mascio
Membro del Collaboration Group
;
Pierluigi Benedetti Panici
Membro del Collaboration Group
;
Flaminia Vena
Membro del Collaboration Group
;
Roberto Brunelli
Membro del Collaboration Group
;
2020

Abstract

Objectives: The primary objective was to quantify the risk of perinatal mortality in non-anomalous monochorionic monoamniotic (MCMA) twin pregnancies complicated by birth-weight (BW) discordance. The secondary objectives were to investigate the effect of inpatient vs outpatient fetal monitoring on the risk of mortality in weight-discordant MCMA twin pregnancies, and to explore the predictive accuracy of BW discordance for perinatal mortality. Methods: This analysis included data on 242 MCMA twin pregnancies (484 fetuses) from three major research collaboratives on twin pregnancy (MONOMONO, STORK and NorSTAMP). The primary outcomes were the risks of intrauterine (IUD), neonatal (NND) and perinatal (PND) death, according to weight discordance at birth from ≥ 10% to ≥ 30%. The secondary outcomes were the association of inpatient vs outpatient fetal monitoring with the risk of mortality in weight-discordant pregnancies, and the accuracy of BW discordance in predicting mortality. Logistic regression and receiver-operating-characteristics-curve analyses were used to analyze the data. Results: The risk of IUD was significantly increased in MCMA twin pregnancies with BW discordance ≥ 10% (odds ratio (OR), 2.2; 95% CI, 1.1-4.4; P = 0.022) and increased up to an OR of 4.4 (95% CI, 1.3-14.4; P = 0.001) in those with BW discordance ≥ 30%. This association remained significant on multivariate logistic regression analysis for BW-discordance cut-offs ≥ 20%. However, weight discordance had low predictive accuracy for mortality, with areas under the receiver-operating-characteristics curve of 0.60 (95% CI, 0.46-0.73), 0.52 (95% CI, 0.33-0.72) and 0.57 (95% CI, 0.45-0.68) for IUD, NND and PND, respectively. There was no difference in the risk of overall IUD, single IUD, double IUD, NND or PND between pregnancies managed as an inpatient compared with those managed as an outpatient, for any BW-discordance cut-off. Conclusions: MCMA twin pregnancies with BW discordance are at increased risk of fetal death, signaling a need for increased levels of monitoring. Despite this, the predictive accuracy for mortality is low; thus, detection of BW discordance alone should not trigger intervention, such as iatrogenic delivery. The current data do not demonstrate an advantage of inpatient over outpatient management in these cases.
2020
cesarean delivery; chorionicity; cord accident; cord entanglement; health care; monochorionic; multiple gestation; perinatal death; respiratory distress syndrome; twin pregnancy
01 Pubblicazione su rivista::01a Articolo in rivista
Weight discordance and perinatal mortality in monoamniotic twin pregnancies: analysis of the MONOMONO, NorSTAMP and STORK multiple pregnancy cohorts / Saccone, Gabriele; Khalil, Asma; Thilanagathan, Basky; Glinianaia, Svetlana; Berghella, Vincenzo; D'Antonio, Francesco; Locci, Mariavittoria; Ghi, Tullio; Frusca, Tiziana; Lanna, Mariano; Faiola, Stefano; Fichera, Anna; Prefumo, Federico; Rizzo, Giuseppe; Bosi, Costanza; Arduino, Bruno; D'Alessandro, Pietro; Borgo, Maria; Arduino, Silvana; Cantanna, Elisabetta; Simonazzi, Giuliana; Rizzo, Nicola; Francesca, Giorgetta; Seravalli, Viola; Miller, Jena L.; Rita Magro‐Malosso, Elena; Di Tommaso, Mariarosaria; Dall'Asta, Andrea; Galli, Letizia; Volpe, Nicola; Visentin, Silvia; Cosmi, Erich; Sarno, Laura; Caissutti, Claudia; Driul, Lorenza; Anastasio, Hannah; DI MASCIO, Daniele; BENEDETTI PANICI, Pierluigi; Vena, Flaminia; Brunelli, Roberto; Ciardulli, Andrea; Schoen, Corina; Suhag, Anju; Maria Gambacorti‐Passerini, Zita; Angeles Anaya Baz, Maria; Magoga, Giulia; Busato, Enrico; Filippi, Elisa; José Rodriguez Suárez, María; Gamez Alderete, Francisco; Alonso Ortuno, Paula; Vitagliano, Amerigo; Mollo, Antonio; Raffone, Antonio; Vendola, Marianne; Navaneethan, Preethi; Wimalasundera, Ruwan; Napolitano, Raffaele; Imma Aquino, Carmen; D'Agostino, Serena; Gallo, Cinzia; Maria Maruotti, Giuseppe; Elena Flacco, Maria; Baschat, Ahmet A.; Venturella, Roberta; Guida, Maurizio; Martinelli, Pasquale; Zullo Therese Hannon, Fulvio; Sturgiss, Stephen N.; Rankin, Judith; Miller, Nicola; Martin, Danielle; Bahamie, Arash; Bhide, Amar; Papageorghiou, Aris; Deans, Anne; Morgan, Kim; Egbor, Michael; Matiluko, Adetunji; Ellis, Cheryl; Gandhi, Hina; Hamid, Rosol; Hutt, Renata; Roberts, Lesley; Pakarian, Faz; Peregrine, Elisabeth. - In: ULTRASOUND IN OBSTETRICS & GYNECOLOGY. - ISSN 0960-7692. - 55:3(2020), pp. 332-338. [10.1002/uog.20357]
File allegati a questo prodotto
File Dimensione Formato  
Saccone_Weight discordance_2020.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 213.26 kB
Formato Adobe PDF
213.26 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1278616
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 19
social impact