Aim: Young patients with operated complex congenital heart defects (CHD) often develop sinus node dysfunction (SND) requiring permanent pacing with rate-responsive function. Activity-driven sensors cannot account for nonmovement stress and cannot modulate heart rate physiologically. Closed Loop Stimulation (CLS, Biotronik, Berlin, Germany) is a physiological rate-responsive pacemaker based on the indirect measure of ventricular contractility. No data are available on the effects of such pacing strategy in young patients. Methods: We report a series of nine patients with CHD and SND who underwent single-chamber CLS-atrial pacing with endocardial or epicardial lead. During the first 30 days, the pacemaker was programmed in AAI pacing mode and then was switched to CLS-atrial pacing mode. An in-hospital control was scheduled 1–2 months later to evaluate the CLS response to neurovegetative stresses (i.e., nonmovement stress [Stroop color test, handgrip] and exercise stress test) and Holter monitor. CLS pacing was compared with rate-responsive accelerometer-driven pacing (AAIR). Results: At telemetric interrogation, CLS pacing showed a more physiological pattern of 24-h heart rate trends than accelerometer sensors. The data obtained during nonmovement/exercise stress demonstrated a physiological increase in the pacing rate with CLS, in synergy with spontaneous events. The accelerometer sensor histogram, during nonmovement stress, showed a “nonresponse” behavior (only lower rate events), and during exercise test showed most events in lower rate range. Holter monitoring showed increase of average and maximum heart rate compared with AAIR. Conclusion: In young CHD patients, endocardial/epicardial CLS-atrial pacing demonstrated a physiological response of heart rate to neurovegetative and physical stresses.

Physiological pacing in young patients with complex congenital heart defects / Silvetti, Massimo Stefano; Pazzano, Vincenzo; Battipaglia, Irma; Di Mambro, Corrado; Calvieri, Camilla; Saputo, Fabio Anselmo; Verticelli, Letizia; Carotti, Adriano; Torcinaro, Sergio; Drago, Fabrizio. - In: PACING AND CLINICAL ELECTROPHYSIOLOGY. - ISSN 0147-8389. - 41:8(2018), pp. 967-977. [10.1111/pace.13409]

Physiological pacing in young patients with complex congenital heart defects

Calvieri, Camilla
Formal Analysis
;
Saputo, Fabio Anselmo
;
2018

Abstract

Aim: Young patients with operated complex congenital heart defects (CHD) often develop sinus node dysfunction (SND) requiring permanent pacing with rate-responsive function. Activity-driven sensors cannot account for nonmovement stress and cannot modulate heart rate physiologically. Closed Loop Stimulation (CLS, Biotronik, Berlin, Germany) is a physiological rate-responsive pacemaker based on the indirect measure of ventricular contractility. No data are available on the effects of such pacing strategy in young patients. Methods: We report a series of nine patients with CHD and SND who underwent single-chamber CLS-atrial pacing with endocardial or epicardial lead. During the first 30 days, the pacemaker was programmed in AAI pacing mode and then was switched to CLS-atrial pacing mode. An in-hospital control was scheduled 1–2 months later to evaluate the CLS response to neurovegetative stresses (i.e., nonmovement stress [Stroop color test, handgrip] and exercise stress test) and Holter monitor. CLS pacing was compared with rate-responsive accelerometer-driven pacing (AAIR). Results: At telemetric interrogation, CLS pacing showed a more physiological pattern of 24-h heart rate trends than accelerometer sensors. The data obtained during nonmovement/exercise stress demonstrated a physiological increase in the pacing rate with CLS, in synergy with spontaneous events. The accelerometer sensor histogram, during nonmovement stress, showed a “nonresponse” behavior (only lower rate events), and during exercise test showed most events in lower rate range. Holter monitoring showed increase of average and maximum heart rate compared with AAIR. Conclusion: In young CHD patients, endocardial/epicardial CLS-atrial pacing demonstrated a physiological response of heart rate to neurovegetative and physical stresses.
2018
cardiac pacing; closed loop stimulation; grown-up congenital heart disease; physiological pacing; rate-responsive pacing; cardiology and cardiovascular medicine
01 Pubblicazione su rivista::01a Articolo in rivista
Physiological pacing in young patients with complex congenital heart defects / Silvetti, Massimo Stefano; Pazzano, Vincenzo; Battipaglia, Irma; Di Mambro, Corrado; Calvieri, Camilla; Saputo, Fabio Anselmo; Verticelli, Letizia; Carotti, Adriano; Torcinaro, Sergio; Drago, Fabrizio. - In: PACING AND CLINICAL ELECTROPHYSIOLOGY. - ISSN 0147-8389. - 41:8(2018), pp. 967-977. [10.1111/pace.13409]
File allegati a questo prodotto
File Dimensione Formato  
Silvetti_Physiological_2018.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.31 MB
Formato Adobe PDF
1.31 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1266544
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact