A highly sensitive nested PCR was carried out in order to detect 2 LTR circles as a marker of recent and ongoing vital replication in HIV-1 infected patients with HIV plasma RNA undetectable. This "in house" two-step nested PCR is very sensitive, but it is not feasible for routine tests and presents a high risk of contamination. In order to reduce the time of reactions and crossover contamination, the possibility was explored to carry out a single step nested PCR, in which the two Successive amplification rounds are carried out in the same tube. This single step nested PCR has the same sensitivity of the two-step nested, is easy to conduct and requires a short time of reaction. The two different PCR methods were compared and the clinical use of monitoring 2 LTR DNA circles in HIV-1 infected patients with undetectable plasma viral load is discussed. (c) 2004 Elsevier B.V. All rights reserved.

One-step nested PCR for detection of 2 LTR circles in PBMCs of HIV-1 infected patients with no detectable plasma HIV RNA / E. A., Lusi; P., Guarascio; Presutti, Carlo; R., Villani; A., Pellicelli; F., Soccorsi. - In: JOURNAL OF VIROLOGICAL METHODS. - ISSN 0166-0934. - 125:1(2005), pp. 11-13. [10.1016/j.jviromet.2004.11.016]

One-step nested PCR for detection of 2 LTR circles in PBMCs of HIV-1 infected patients with no detectable plasma HIV RNA

PRESUTTI, Carlo;
2005

Abstract

A highly sensitive nested PCR was carried out in order to detect 2 LTR circles as a marker of recent and ongoing vital replication in HIV-1 infected patients with HIV plasma RNA undetectable. This "in house" two-step nested PCR is very sensitive, but it is not feasible for routine tests and presents a high risk of contamination. In order to reduce the time of reactions and crossover contamination, the possibility was explored to carry out a single step nested PCR, in which the two Successive amplification rounds are carried out in the same tube. This single step nested PCR has the same sensitivity of the two-step nested, is easy to conduct and requires a short time of reaction. The two different PCR methods were compared and the clinical use of monitoring 2 LTR DNA circles in HIV-1 infected patients with undetectable plasma viral load is discussed. (c) 2004 Elsevier B.V. All rights reserved.
2005
2 ltr circles; hiv; new marker
01 Pubblicazione su rivista::01a Articolo in rivista
One-step nested PCR for detection of 2 LTR circles in PBMCs of HIV-1 infected patients with no detectable plasma HIV RNA / E. A., Lusi; P., Guarascio; Presutti, Carlo; R., Villani; A., Pellicelli; F., Soccorsi. - In: JOURNAL OF VIROLOGICAL METHODS. - ISSN 0166-0934. - 125:1(2005), pp. 11-13. [10.1016/j.jviromet.2004.11.016]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/125161
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 7
social impact