Background: Locking plates are the gold standard for treatment of 3-part humeral head fractures, although major complications range from 9% to 36%. Percutaneous techniques may allow vascular supply preservation, maintenance of fracture hematoma, scarce blood loss. Many configurations with Kirschner wires can be performed, generating confusion on result interpretation. We studied the correlation between system configuration, stability, and clinical results in patients with 3-part humeral head fractures treated with the same fixation system but with 2 different biomechanical constructs. Materials and methods: There were 52 consecutive patients (19 men, 33 women; mean age, 63.1 [standard deviation, 5.6] years; range, 48-82 years) with Hertel 7 humeral head fractures. Two fixation constructs composed of 3 couples (construct A) or 4 couples (construct B) of blocked threaded wires were used in 17 and 35 patients, respectively. At the final follow-up, the individual relative Constant Score (irCS) and visual analog scale were measured. Radiographic evaluation according to the Bahr criteria was performed. Statistical analysis was performed. Results: The mean follow-up was 22 months. The mean irCS at the final follow-up was 89.7%. The mean irCS in patients treated with construct A and construct B was 86% and 93%, respectively (P =.043). One nonunion and 2 superficial infections occurred (6%). The postoperative reduction was excellent in 97% of patients and remained excellent in 89%. The mean postoperative neck shaft angle was 135.0° (construct A: 134.7°; construct B: 135.1°), and the final neck shaft angle was 132.9° (construct A: 131.3°; construct B: 133.8°; P =.047). Conclusions: The functional and radiologic outcomes obtained with percutaneous fixation or locking plates are similar; however, the percentage of major complications after percutaneous treatment is lower. Results of percutaneous fixation depend on the biomechanical construct.

Complex humeral head fractures treated with blocked threaded wires: maintenance of the reduction and clinical results with two different fixation constructs / Gumina, Stefano; Candela, Vittorio; Giannicola, Giuseppe; Orsina, Luigi; Passaretti, Daniele; Villani, Ciro. - In: JOURNAL OF SHOULDER AND ELBOW SURGERY. - ISSN 1058-2746. - 28:1(2019), pp. 36-41. [10.1016/j.jse.2018.06.034]

Complex humeral head fractures treated with blocked threaded wires: maintenance of the reduction and clinical results with two different fixation constructs

Gumina, Stefano;Candela, Vittorio;Giannicola, Giuseppe;Orsina, Luigi;Passaretti, Daniele;Villani, Ciro
2019

Abstract

Background: Locking plates are the gold standard for treatment of 3-part humeral head fractures, although major complications range from 9% to 36%. Percutaneous techniques may allow vascular supply preservation, maintenance of fracture hematoma, scarce blood loss. Many configurations with Kirschner wires can be performed, generating confusion on result interpretation. We studied the correlation between system configuration, stability, and clinical results in patients with 3-part humeral head fractures treated with the same fixation system but with 2 different biomechanical constructs. Materials and methods: There were 52 consecutive patients (19 men, 33 women; mean age, 63.1 [standard deviation, 5.6] years; range, 48-82 years) with Hertel 7 humeral head fractures. Two fixation constructs composed of 3 couples (construct A) or 4 couples (construct B) of blocked threaded wires were used in 17 and 35 patients, respectively. At the final follow-up, the individual relative Constant Score (irCS) and visual analog scale were measured. Radiographic evaluation according to the Bahr criteria was performed. Statistical analysis was performed. Results: The mean follow-up was 22 months. The mean irCS at the final follow-up was 89.7%. The mean irCS in patients treated with construct A and construct B was 86% and 93%, respectively (P =.043). One nonunion and 2 superficial infections occurred (6%). The postoperative reduction was excellent in 97% of patients and remained excellent in 89%. The mean postoperative neck shaft angle was 135.0° (construct A: 134.7°; construct B: 135.1°), and the final neck shaft angle was 132.9° (construct A: 131.3°; construct B: 133.8°; P =.047). Conclusions: The functional and radiologic outcomes obtained with percutaneous fixation or locking plates are similar; however, the percentage of major complications after percutaneous treatment is lower. Results of percutaneous fixation depend on the biomechanical construct.
2019
Hertel 7 fractures; humeral head perfusion; Level III; percutaneous pinning; percutaneous wires fixation; plate fixation of humeral fractures; proximal humeral fracture fixation; Retrospective Cohort Design; shoulder fracture fixation; Three-part proximal humeral fractures; Treatment Study; Aged; Aged, 80 and over; Female; Fracture Fixation, Internal; Humans; Humeral Fractures; Humeral Head; Male; Middle Aged; Radiography; Reconstructive Surgical Procedures; Bone Plates; Bone Wires; Surgery; Orthopedics and Sports Medicine
01 Pubblicazione su rivista::01a Articolo in rivista
Complex humeral head fractures treated with blocked threaded wires: maintenance of the reduction and clinical results with two different fixation constructs / Gumina, Stefano; Candela, Vittorio; Giannicola, Giuseppe; Orsina, Luigi; Passaretti, Daniele; Villani, Ciro. - In: JOURNAL OF SHOULDER AND ELBOW SURGERY. - ISSN 1058-2746. - 28:1(2019), pp. 36-41. [10.1016/j.jse.2018.06.034]
File allegati a questo prodotto
File Dimensione Formato  
Gumina_Complex-humeral_2019.pdf

Open Access dal 01/04/2023

Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 689.17 kB
Formato Adobe PDF
689.17 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1249702
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 4
social impact