The aim of this study is to compare the accuracy of the standard visual scoring of computed tomography (CT) scans with a cloud-based quantitative CT analysis that uses the StratX software, to measure collateral ventilation and, thus, predict lobar atelectasis after valve treatment.

Visual analysis versus quantitative CT analysis of interlobar fissure integrity in selecting emphysematous patients for endobronchial valve treatment / Fiorelli, Alfonso; Poggi, Camilla; Anile, Marco; Cascone, Roberto; Carlucci, Annalisa; Cassiano, Francesco; Andreetti, Claudio; Tiracorrendo, Matteo; Diso, Daniele; Serra, Nicola; Venuta, Federico; Rendina, Erino Angelo; Santini, Mario; D'Andrilli, Antonio. - In: INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY. - ISSN 1569-9293. - (2018). [10.1093/icvts/ivy340]

Visual analysis versus quantitative CT analysis of interlobar fissure integrity in selecting emphysematous patients for endobronchial valve treatment

Poggi, Camilla;Anile, Marco;Cassiano, Francesco;Andreetti, Claudio;Tiracorrendo, Matteo;Diso, Daniele;Serra, Nicola;Venuta, Federico;Rendina, Erino Angelo;D'Andrilli, Antonio
2018

Abstract

The aim of this study is to compare the accuracy of the standard visual scoring of computed tomography (CT) scans with a cloud-based quantitative CT analysis that uses the StratX software, to measure collateral ventilation and, thus, predict lobar atelectasis after valve treatment.
2018
: Zephyr endobronchial valves • Bronchoscopy lung volume reduction • Emphysema • Collateral ventilation • Fissure analysis
01 Pubblicazione su rivista::01a Articolo in rivista
Visual analysis versus quantitative CT analysis of interlobar fissure integrity in selecting emphysematous patients for endobronchial valve treatment / Fiorelli, Alfonso; Poggi, Camilla; Anile, Marco; Cascone, Roberto; Carlucci, Annalisa; Cassiano, Francesco; Andreetti, Claudio; Tiracorrendo, Matteo; Diso, Daniele; Serra, Nicola; Venuta, Federico; Rendina, Erino Angelo; Santini, Mario; D'Andrilli, Antonio. - In: INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY. - ISSN 1569-9293. - (2018). [10.1093/icvts/ivy340]
File allegati a questo prodotto
File Dimensione Formato  
Fiorelli_Visual-versus-CT_2018.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 974.02 kB
Formato Adobe PDF
974.02 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1248923
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 10
social impact