Data on perioperative outcomes of new mesh-covered carotid stents have been presented, showing encouraging results1,2. Major complication rates in CGuard carotid artery stenting (CAS) procedures range from 0 to 2.5% at 30 days1,2. These data underline the feasibility and safety of the CGuard™ stent (InspireMD, Tel Aviv, Israel) in preventing off-table events in the so-called plaque healing period, that is to say after the intraoperative embolism risk has been overcome. The IRON-Guard registry2 has continued to collect data from the first 200 patients treated by CGuard stent implantation. The present paper reports

Twelve-month results of the Italian registry on protected CAS with the mesh-covered CGuard stent.The IRON-Guard study / Capoccia, Laura; Sirignano, Pasqualino; Mansour, Wassim; Sbarigia, Enrico; Speziale, Francesco. - In: EUROINTERVENTION. - ISSN 1774-024X. - 14:10(2018), pp. 1150-1152. [10.4244/EIJ-D-18-00241]

Twelve-month results of the Italian registry on protected CAS with the mesh-covered CGuard stent.The IRON-Guard study

Capoccia, Laura
;
Sirignano, Pasqualino;Mansour, Wassim;Sbarigia, Enrico;Speziale, Francesco
2018

Abstract

Data on perioperative outcomes of new mesh-covered carotid stents have been presented, showing encouraging results1,2. Major complication rates in CGuard carotid artery stenting (CAS) procedures range from 0 to 2.5% at 30 days1,2. These data underline the feasibility and safety of the CGuard™ stent (InspireMD, Tel Aviv, Israel) in preventing off-table events in the so-called plaque healing period, that is to say after the intraoperative embolism risk has been overcome. The IRON-Guard registry2 has continued to collect data from the first 200 patients treated by CGuard stent implantation. The present paper reports
2018
Cardiology and Cardiovascular Medicine; carotid stents; carotid artery stenting (CAS)
01 Pubblicazione su rivista::01m Editorial/Introduzione in rivista
Twelve-month results of the Italian registry on protected CAS with the mesh-covered CGuard stent.The IRON-Guard study / Capoccia, Laura; Sirignano, Pasqualino; Mansour, Wassim; Sbarigia, Enrico; Speziale, Francesco. - In: EUROINTERVENTION. - ISSN 1774-024X. - 14:10(2018), pp. 1150-1152. [10.4244/EIJ-D-18-00241]
File allegati a questo prodotto
File Dimensione Formato  
Capoccia_CGuard-stent-results_2018.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.58 MB
Formato Adobe PDF
1.58 MB Adobe PDF   Contatta l'autore