Abstract Treatment targets in functional neurosurgery usually consist of selected structures within the thalamus and basal ganglia, which can be stimulated in order to affect specific brain pathways. Chronic electrical stimulation of these structures is a widely used approach for selected patients with advanced movement disorders. An alternative therapeutic solution consists of producing a lesion in the target nucleus, for example by means of radiosurgery, a noninvasive procedure, and this prevents the use of intraoperative microelectrode recording as a method for accurate target definition. The need to have accurate noninvasive localization of the target motivated our previous work on atlas-based identification; the aim of this present work is to provide additional validation of this approach based on the identification of the red nuclei (RN), which are located near the subthalamic nucleus (STN). Coordinates of RN were obtained from the Talairach and Tournoux (TT) atlas and transformed into the coordinates of the Montreal Neurological Institute (MNI) atlas, creating a mask representation of RN. The MNI atlas volume was nonrigidly registered onto the patient magnetic resonance imaging (MRI). This deformation field was then applied to the RN mask, providing its location on the patient MRI. Because RN are easily identifiable on 1.5 T T2-MRI images, they were manually delineated; the coordinates of the centers of mass of the manually and automatically identified structures were compared. Additionally, volumetric overlapping indices were calculated. Ten patients were examined by this technique. All indices indicated a high level of agreement between manually and automatically identified structures. These results not only confirm the accuracy of the method but also allow fine tuning of the automatic identification method to be performed.

Direct validation of atlas-based red nucleus identification for functional radiosurgery / Joseph, Stancanello; Pantaleo, Romanelli; Fabio, Sebastiano; Nicola, Modugno; Alexander, Muacevic; Pietro, Cerveri; Esposito, Vincenzo; Giancarlo, Ferrigno; Fulvio, Uggeri; Cantore, Giampaolo. - In: MEDICAL PHYSICS. - ISSN 0094-2405. - 34:8(2007), pp. 3143-3148. [10.1118/1.2750971]

Direct validation of atlas-based red nucleus identification for functional radiosurgery

ESPOSITO, Vincenzo;CANTORE, Giampaolo
2007

Abstract

Abstract Treatment targets in functional neurosurgery usually consist of selected structures within the thalamus and basal ganglia, which can be stimulated in order to affect specific brain pathways. Chronic electrical stimulation of these structures is a widely used approach for selected patients with advanced movement disorders. An alternative therapeutic solution consists of producing a lesion in the target nucleus, for example by means of radiosurgery, a noninvasive procedure, and this prevents the use of intraoperative microelectrode recording as a method for accurate target definition. The need to have accurate noninvasive localization of the target motivated our previous work on atlas-based identification; the aim of this present work is to provide additional validation of this approach based on the identification of the red nuclei (RN), which are located near the subthalamic nucleus (STN). Coordinates of RN were obtained from the Talairach and Tournoux (TT) atlas and transformed into the coordinates of the Montreal Neurological Institute (MNI) atlas, creating a mask representation of RN. The MNI atlas volume was nonrigidly registered onto the patient magnetic resonance imaging (MRI). This deformation field was then applied to the RN mask, providing its location on the patient MRI. Because RN are easily identifiable on 1.5 T T2-MRI images, they were manually delineated; the coordinates of the centers of mass of the manually and automatically identified structures were compared. Additionally, volumetric overlapping indices were calculated. Ten patients were examined by this technique. All indices indicated a high level of agreement between manually and automatically identified structures. These results not only confirm the accuracy of the method but also allow fine tuning of the automatic identification method to be performed.
2007
atlas-based identification; functional radiosurgery; nonrigid registration; red nucleus
01 Pubblicazione su rivista::01a Articolo in rivista
Direct validation of atlas-based red nucleus identification for functional radiosurgery / Joseph, Stancanello; Pantaleo, Romanelli; Fabio, Sebastiano; Nicola, Modugno; Alexander, Muacevic; Pietro, Cerveri; Esposito, Vincenzo; Giancarlo, Ferrigno; Fulvio, Uggeri; Cantore, Giampaolo. - In: MEDICAL PHYSICS. - ISSN 0094-2405. - 34:8(2007), pp. 3143-3148. [10.1118/1.2750971]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/122210
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact